01
8 of 18 parameters
What actually differs
Parameter
SG40CX-P3-CN
MID 40KTL3-X
Difference
Max input current per tracker
40.0 A
26.0 A
14.0 A more headroom
Weight
40.0 kg
30.5 kg
9.5 kg lighter
Nominal AC voltage
380 V
400 V
20 V apart
Start voltage
200 V
250 V
50 V earlier start
Max efficiency
98.6 %
98.8 %
0.2 pp more efficient
Weight per kW
1.0 kg/kW
0.8 kg/kW
0.2 kg/kW lighter
MPPT voltage range
160-1000 V
200-1000 V
160-1000 V vs 200-1000 V
Dimensions
595x645x245 mm
435x580x230 mm
595x645x245 mm vs 435x580x230 mm
02
Full specification
Parameter
SG40CX-P3-CN
MID 40KTL3-X
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
44.00 kW
44.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
380 V
400 V
20 V apart
Max AC current
66.9 A
66.6 A
Effectively the same
PV input
Max PV power
-
60.00 kW
Not published by Sungrow
DC/AC ratio
-
1.50
Not published by Sungrow
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
160-1000 V
200-1000 V
160-1000 V vs 200-1000 V
Start voltage
200 V
250 V
-50 V for SG40CX-P3-CN
MPP trackers
4
-
Not published by Growatt
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
26.0 A
+14.0 A for SG40CX-P3-CN
Efficiency
European efficiency
-
98.5 %
Not published by Sungrow
Max efficiency
98.6 %
98.8 %
+0.2 pp for MID 40KTL3-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
40.0 kg
30.5 kg
-9.5 kg for MID 40KTL3-X
Weight per kW
1.0 kg/kW
0.8 kg/kW
-0.2 kg/kW for MID 40KTL3-X
Dimensions
595x645x245 mm
435x580x230 mm
595x645x245 mm vs 435x580x230 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
60 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
Yes
Not published by Sungrow
Arc fault protection
-
Yes
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Sungrow SG40CX-P3-CN vs Huawei SUN2000-40KTL-M3
8 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Sungrow SG40CX-P3-CN vs Solis-40K
7 differences, the largest is weight
Same type, similar size
Sungrow
Sungrow SG40CX-P3-CN vs Sungrow SG40CX-P2
3 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MID 40KTL3-X vs Sungrow SG40CX
5 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.