Growatt MID 40KTL3-X vs Sungrow SG40CX-P3-CN
VS
The verdict
8 differences, and they point both ways
The largest is max input current per tracker: 14.0 A more headroom. 10 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
10
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 18 parameters
What actually differs
Parameter
MID 40KTL3-X
SG40CX-P3-CN
Difference
Max input current per tracker
26.0 A
40.0 A
14.0 A more headroom
Weight
30.5 kg
40.0 kg
9.5 kg lighter
Nominal AC voltage
400 V
380 V
20 V apart
Start voltage
250 V
200 V
50 V earlier start
Max efficiency
98.8 %
98.6 %
0.2 pp more efficient
Weight per kW
0.8 kg/kW
1.0 kg/kW
0.2 kg/kW lighter
MPPT voltage range
200-1000 V
160-1000 V
200-1000 V vs 160-1000 V
Dimensions
435x580x230 mm
595x645x245 mm
435x580x230 mm vs 595x645x245 mm
02
Full specification
Parameter
MID 40KTL3-X
SG40CX-P3-CN
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
44.00 kW
44.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
380 V
20 V apart
Max AC current
66.6 A
66.9 A
Effectively the same
PV input
Max PV power
60.00 kW
-
Not published by Sungrow
DC/AC ratio
1.50
-
Not published by Sungrow
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
160-1000 V
200-1000 V vs 160-1000 V
Start voltage
250 V
200 V
-50 V for SG40CX-P3-CN
MPP trackers
-
4
Not published by Growatt
Strings per tracker
2
2
Same
Max input current per tracker
26.0 A
40.0 A
+14.0 A for SG40CX-P3-CN
Efficiency
European efficiency
98.5 %
-
Not published by Sungrow
Max efficiency
98.8 %
98.6 %
+0.2 pp for MID 40KTL3-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
30.5 kg
40.0 kg
-9.5 kg for MID 40KTL3-X
Weight per kW
0.8 kg/kW
1.0 kg/kW
-0.2 kg/kW for MID 40KTL3-X
Dimensions
435x580x230 mm
595x645x245 mm
435x580x230 mm vs 595x645x245 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
60 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Sungrow
Ethernet
Yes
-
Not published by Sungrow
Arc fault protection
Yes
-
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Growatt MID 40KTL3-X vs Huawei SUN2000-40KTL-M3
7 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Growatt MID 40KTL3-X vs Solis-40K
7 differences, the largest is max pv power
Same type, similar size
Sungrow
Growatt MID 40KTL3-X vs Sungrow SG40CX-P2
10 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.