Sungrow SG40CX-P2 vs SOFAR 40KTLX-G4-LV
VS
The verdict
11 differences, and they point both ways
The largest is max dc voltage: 200 V apart. 12 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
12
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 23 parameters
What actually differs
Parameter
SG40CX-P2
SOFAR 40KTLX-G4-LV
Difference
Max DC voltage
1100 V
900 V
200 V apart
Max input current per tracker
30.0 A
40.0 A
10.0 A more headroom
Max PV power
56.00 kW
60.00 kW
4.00 kW apart
Weight
40.0 kg
75.0 kg
35.0 kg lighter
Weight per kW
1.0 kg/kW
1.9 kg/kW
0.9 kg/kW lighter
European efficiency
98.3 %
98.0 %
0.3 pp more efficient
DC/AC ratio
1.40
1.50
0.10 more oversizing headroom
Nominal AC voltage
400 V
220 V
180 V apart
Max AC current
66.9 A
115.5 A
48.6 A apart
MPPT voltage range
160-1000 V
180-800 V
160-1000 V vs 180-800 V
Dimensions
575x645x245 mm
695x970x325 mm
575x645x245 mm vs 695x970x325 mm
02
Full specification
Parameter
SG40CX-P2
SOFAR 40KTLX-G4-LV
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
44.00 kW
44.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
220 V
180 V apart
Max AC current
66.9 A
115.5 A
48.6 A apart
PV input
Max PV power
56.00 kW
60.00 kW
4.00 kW apart
DC/AC ratio
1.40
1.50
+0.10 for SOFAR 40KTLX-G4-LV
Max DC voltage
1100 V
900 V
200 V apart
MPPT voltage range
160-1000 V
180-800 V
160-1000 V vs 180-800 V
Start voltage
200 V
200 V
Same
MPP trackers
4
-
Not published by Sofar Solar
Strings per tracker
2
2
Same
Max input current per tracker
30.0 A
40.0 A
+10.0 A for SOFAR 40KTLX-G4-LV
Efficiency
European efficiency
98.3 %
98.0 %
+0.3 pp for SG40CX-P2
Max efficiency
98.5 %
98.5 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
40.0 kg
75.0 kg
-35.0 kg for SG40CX-P2
Weight per kW
1.0 kg/kW
1.9 kg/kW
-0.9 kg/kW for SG40CX-P2
Dimensions
575x645x245 mm
695x970x325 mm
575x645x245 mm vs 695x970x325 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Sofar Solar
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG40CX-P2 vs Growatt MID 40KTL3-X
10 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Sungrow SG40CX-P2 vs Huawei SUN2000-40KTL-M3
8 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Sungrow SG40CX-P2 vs Solis-40K
8 differences, the largest is max pv power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.