Skip to main content
SOFAR 40KTLX-G4-LV vs SG40CX-P2 12 of 23 identical Swap Change inverters

SOFAR 40KTLX-G4-LV vs Sungrow SG40CX-P2

SOFAR 40KTLX-G4-LV
Sofar Solar
SOFAR 40KTLX-G4-LV
40 kW 98.0 % euro Grid-tie
VS
Sungrow SG40CX-P2
Sungrow
SG40CX-P2
40 kW 98.3 % euro Grid-tie
The verdict

11 differences, and they point both ways

The largest is max dc voltage: 200 V apart. 12 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
12 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 23 parameters
Parameter SOFAR 40KTLX-G4-LV SG40CX-P2 Difference
Max DC voltage 900 V 1100 V 200 V apart
Max input current per tracker 40.0 A 30.0 A 10.0 A more headroom
Max PV power 60.00 kW 56.00 kW 4.00 kW apart
Weight 75.0 kg 40.0 kg 35.0 kg lighter
Weight per kW 1.9 kg/kW 1.0 kg/kW 0.9 kg/kW lighter
European efficiency 98.0 % 98.3 % 0.3 pp more efficient
DC/AC ratio 1.50 1.40 0.10 more oversizing headroom
Nominal AC voltage 220 V 400 V 180 V apart
Max AC current 115.5 A 66.9 A 48.6 A apart
MPPT voltage range 180-800 V 160-1000 V 180-800 V vs 160-1000 V
Dimensions 695x970x325 mm 575x645x245 mm 695x970x325 mm vs 575x645x245 mm
02

Full specification

Parameter SOFAR 40KTLX-G4-LV SG40CX-P2 Difference
AC output
Rated AC power 40.00 kW 40.00 kW Same
Max AC power 44.00 kW 44.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 220 V 400 V 180 V apart
Max AC current 115.5 A 66.9 A 48.6 A apart
PV input
Max PV power 60.00 kW 56.00 kW 4.00 kW apart
DC/AC ratio 1.50 1.40 +0.10 for SOFAR 40KTLX-G4-LV
Max DC voltage 900 V 1100 V 200 V apart
MPPT voltage range 180-800 V 160-1000 V 180-800 V vs 160-1000 V
Start voltage 200 V 200 V Same
MPP trackers - 4 Not published by Sofar Solar
Strings per tracker 2 2 Same
Max input current per tracker 40.0 A 30.0 A +10.0 A for SOFAR 40KTLX-G4-LV
Efficiency
European efficiency 98.0 % 98.3 % +0.3 pp for SG40CX-P2
Max efficiency 98.5 % 98.5 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 75.0 kg 40.0 kg -35.0 kg for SG40CX-P2
Weight per kW 1.9 kg/kW 1.0 kg/kW -0.9 kg/kW for SG40CX-P2
Dimensions 695x970x325 mm 575x645x245 mm 695x970x325 mm vs 575x645x245 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Sofar Solar
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
SOFAR 40KTLX-G4-LV vs Growatt MID 40KTL3-X
11 differences, the largest is european efficiency
Same type, similar size
Huawei
SOFAR 40KTLX-G4-LV vs Huawei SUN2000-40KTL-M3
12 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
SOFAR 40KTLX-G4-LV vs Solis-40K
12 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Sungrow SG40CX-P2 vs Sungrow SG40CX
6 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.