Sungrow SG125CX-P2 vs Growatt MAX 125KTL3-X2 MV
VS
The verdict
MAX 125KTL3-X2 MV leads on the differences that matter
The largest is mpp trackers: 4 trackers more. 12 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
12
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 19 parameters
What actually differs
Parameter
SG125CX-P2
MAX 125KTL3-X2 MV
Difference
MPP trackers
12
8
4 trackers more
Max input current per tracker
30.0 A
45.0 A
15.0 A more headroom
Weight
93.0 kg
84.0 kg
9.0 kg lighter
Max efficiency
98.5 %
99.0 %
0.5 pp more efficient
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
181.1 A
165.4 A
15.7 A apart
Dimensions
795x1020x360 mm
640x970x345 mm
795x1020x360 mm vs 640x970x345 mm
02
Full specification
Parameter
SG125CX-P2
MAX 125KTL3-X2 MV
Difference
AC output
Rated AC power
125.00 kW
125.00 kW
Same
Max AC power
125.00 kW
125.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
181.1 A
165.4 A
15.7 A apart
PV input
Max PV power
175.00 kW
-
Not published by Growatt
DC/AC ratio
1.40
-
Not published by Growatt
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
180-1000 V
180-1000 V
Same
Start voltage
200 V
195 V
Effectively the same
MPP trackers
12
8
+4 trackers for SG125CX-P2
Strings per tracker
2
2
Same
Max input current per tracker
30.0 A
45.0 A
+15.0 A for MAX 125KTL3-X2 MV
Efficiency
European efficiency
98.3 %
-
Not published by Growatt
Max efficiency
98.5 %
99.0 %
+0.5 pp for MAX 125KTL3-X2 MV
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
93.0 kg
84.0 kg
-9.0 kg for MAX 125KTL3-X2 MV
Weight per kW
0.7 kg/kW
0.7 kg/kW
Same
Dimensions
795x1020x360 mm
640x970x345 mm
795x1020x360 mm vs 640x970x345 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Sungrow SG125CX-P2 vs Ginlong Solis S5-GC125K-HV
8 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Sungrow SG125CX-P2 vs Growatt MAX 125KTL3-X LV
5 differences, the largest is max input current per tracker
Same type, similar size
Sofar Solar
Sungrow SG125CX-P2 vs SOFAR 125KTLX-G4-A
5 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.