Skip to main content
SG125CX-P2 vs SOFAR 125KTLX-G4-A 16 of 21 identical Swap Change inverters

Sungrow SG125CX-P2 vs SOFAR 125KTLX-G4-A

Sungrow SG125CX-P2
Sungrow
SG125CX-P2
125 kW 98.3 % euro Grid-tie
VS
SOFAR 125KTLX-G4-A
Sofar Solar
SOFAR 125KTLX-G4-A
125 kW 98.3 % euro Grid-tie
The verdict

SOFAR 125KTLX-G4-A leads on the differences that matter

The largest is max input current per tracker: 10.0 A more headroom. 16 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 5 differences
How alike are they
16 of 21 comparable
parameters are identical
identical differs not published
01

What actually differs

5 of 21 parameters
Parameter SG125CX-P2 SOFAR 125KTLX-G4-A Difference
Max input current per tracker 30.0 A 40.0 A 10.0 A more headroom
MPP trackers 12 10 2 trackers more
Weight 93.0 kg 75.0 kg 18.0 kg lighter
Max AC current 181.1 A 190.0 A 8.9 A apart
Dimensions 795x1020x360 mm 695x970x325 mm 795x1020x360 mm vs 695x970x325 mm
02

Full specification

Parameter SG125CX-P2 SOFAR 125KTLX-G4-A Difference
AC output
Rated AC power 125.00 kW 125.00 kW Same
Max AC power 125.00 kW 125.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 181.1 A 190.0 A 8.9 A apart
PV input
Max PV power 175.00 kW - Not published by Sofar Solar
DC/AC ratio 1.40 - Not published by Sofar Solar
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 180-1000 V 180-1000 V Same
Start voltage 200 V 200 V Same
MPP trackers 12 10 +2 trackers for SG125CX-P2
Strings per tracker 2 2 Same
Max input current per tracker 30.0 A 40.0 A +10.0 A for SOFAR 125KTLX-G4-A
Efficiency
European efficiency 98.3 % 98.3 % Same
Max efficiency 98.5 % 98.6 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 93.0 kg 75.0 kg -18.0 kg for SOFAR 125KTLX-G4-A
Weight per kW 0.7 kg/kW 0.6 kg/kW Effectively the same
Dimensions 795x1020x360 mm 695x970x325 mm 795x1020x360 mm vs 695x970x325 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Sungrow
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
Sungrow SG125CX-P2 vs Ginlong Solis S5-GC125K-HV
8 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Sungrow SG125CX-P2 vs Growatt MAX 125KTL3-X LV
5 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Sungrow SG125CX-P2 vs Ginlong Solis S6-GC125K
8 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.