Sungrow SG125CX-P2 vs Growatt MAX 124KTL3-X2 MV
VS
The verdict
MAX 124KTL3-X2 MV leads on the differences that matter
The largest is rated ac power: 1.00 kW apart. 11 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
11
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 23 parameters
What actually differs
Parameter
SG125CX-P2
MAX 124KTL3-X2 MV
Difference
Rated AC power
125.00 kW
124.00 kW
1.00 kW apart
MPP trackers
12
8
4 trackers more
Max input current per tracker
30.0 A
45.0 A
15.0 A more headroom
Max AC power
125.00 kW
124.00 kW
1.00 kW apart
Max PV power
175.00 kW
186.00 kW
11.00 kW apart
Weight
93.0 kg
84.0 kg
9.0 kg lighter
Max efficiency
98.5 %
99.0 %
0.5 pp more efficient
European efficiency
98.3 %
98.5 %
0.2 pp more efficient
DC/AC ratio
1.40
1.50
0.10 more oversizing headroom
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
181.1 A
164.1 A
17.0 A apart
Dimensions
795x1020x360 mm
640x970x345 mm
795x1020x360 mm vs 640x970x345 mm
02
Full specification
Parameter
SG125CX-P2
MAX 124KTL3-X2 MV
Difference
AC output
Rated AC power
125.00 kW
124.00 kW
1.00 kW apart
Max AC power
125.00 kW
124.00 kW
1.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
181.1 A
164.1 A
17.0 A apart
PV input
Max PV power
175.00 kW
186.00 kW
11.00 kW apart
DC/AC ratio
1.40
1.50
+0.10 for MAX 124KTL3-X2 MV
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
180-1000 V
180-1000 V
Same
Start voltage
200 V
195 V
Effectively the same
MPP trackers
12
8
+4 trackers for SG125CX-P2
Strings per tracker
2
2
Same
Max input current per tracker
30.0 A
45.0 A
+15.0 A for MAX 124KTL3-X2 MV
Efficiency
European efficiency
98.3 %
98.5 %
+0.2 pp for MAX 124KTL3-X2 MV
Max efficiency
98.5 %
99.0 %
+0.5 pp for MAX 124KTL3-X2 MV
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
93.0 kg
84.0 kg
-9.0 kg for MAX 124KTL3-X2 MV
Weight per kW
0.7 kg/kW
0.7 kg/kW
Same
Dimensions
795x1020x360 mm
640x970x345 mm
795x1020x360 mm vs 640x970x345 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Sungrow SG125CX-P2 vs Ginlong Solis S5-GC125K-HV
8 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Sungrow SG125CX-P2 vs Growatt MAX 125KTL3-X LV
5 differences, the largest is max input current per tracker
Same type, similar size
Sofar Solar
Sungrow SG125CX-P2 vs SOFAR 125KTLX-G4-A
5 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.