Skip to main content
SG110CX vs GW100K-GT-CN-G20 11 of 18 identical Swap Change inverters

Sungrow SG110CX vs GoodWe GW100K-GT-CN-G20

Sungrow SG110CX
Sungrow
SG110CX
100 kW 98.5 % euro Grid-tie
VS
GoodWe
GW100K-GT-CN-G20
100 kW Grid-tie
The verdict

GW100K-GT-CN-G20 leads on the differences that matter

The largest is max input current per tracker: 16.0 A more headroom. 11 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.

See all 7 differences
How alike are they
11 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

7 of 18 parameters
Parameter SG110CX GW100K-GT-CN-G20 Difference
Max input current per tracker 26.0 A 42.0 A 16.0 A more headroom
Weight 89.0 kg 81.0 kg 8.0 kg lighter
Nominal AC voltage 400 V 380 V 20 V apart
Max AC current 158.8 A 167.1 A 8.3 A apart
Start voltage 250 V 200 V 50 V earlier start
MPPT voltage range 200-1000 V 180-1000 V 200-1000 V vs 180-1000 V
Dimensions 660x1051x362 mm 758x995x358 mm 660x1051x362 mm vs 758x995x358 mm
02

Full specification

Parameter SG110CX GW100K-GT-CN-G20 Difference
AC output
Rated AC power 100.00 kW 100.00 kW Same
Max AC power 110.00 kW 110.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 380 V 20 V apart
Max AC current 158.8 A 167.1 A 8.3 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-1000 V 180-1000 V 200-1000 V vs 180-1000 V
Start voltage 250 V 200 V -50 V for GW100K-GT-CN-G20
MPP trackers 9 - Not published by GoodWe
Strings per tracker 2 2 Same
Max input current per tracker 26.0 A 42.0 A +16.0 A for GW100K-GT-CN-G20
Efficiency
European efficiency 98.5 % - Not published by GoodWe
Max efficiency 98.7 % 98.8 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 89.0 kg 81.0 kg -8.0 kg for GW100K-GT-CN-G20
Weight per kW 0.9 kg/kW 0.8 kg/kW Effectively the same
Dimensions 660x1051x362 mm 758x995x358 mm 660x1051x362 mm vs 758x995x358 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - 60 dB Not published by Sungrow
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by GoodWe
Ethernet Yes - Not published by GoodWe
Arc fault protection - Yes Not published by Sungrow
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Sungrow SG110CX vs Huawei SUN2000-100KTL-M2
6 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Sungrow SG110CX vs Huawei SUN2000-100KTL-M1 (@480 V)
5 differences, the largest is max ac current
Same type, similar size
SMA Solar
Sungrow SG110CX vs SMA Solar Sunny Highpower PEAK3 SHP 100-21
8 differences, the largest is mpp trackers
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.