SolarEdge SE90K (for 220V/230V line-to-line grids) vs Growatt MAX 50KTL3 LV

SolarEdge
SE90K (for 220V/230V line-to-line grids)
51.9 kW
98.0 % euro
Grid-tie
VS
The verdict
MAX 50KTL3 LV leads on the differences that matter
The largest is rated ac power: 1.90 kW apart. 6 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
6
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 16 parameters
What actually differs
Parameter
SE90K (for 220V/230V line-to-line grids)
MAX 50KTL3 LV
Difference
Rated AC power
51.90 kW
50.00 kW
1.90 kW apart
Max DC voltage
600 V
1100 V
500 V apart
European efficiency
98.0 %
98.4 %
0.4 pp more efficient
Max AC power
51.90 kW
55.50 kW
3.60 kW apart
Max PV power
90.83 kW
75.00 kW
15.83 kW apart
DC/AC ratio
1.75
1.50
0.25 more oversizing headroom
Max efficiency
98.3 %
98.8 %
0.5 pp more efficient
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
130.5 A
80.5 A
50.0 A apart
MPPT voltage range
370-600 V
200-1000 V
370-600 V vs 200-1000 V
02
Full specification
Parameter
SE90K (for 220V/230V line-to-line grids)
MAX 50KTL3 LV
Difference
AC output
Rated AC power
51.90 kW
50.00 kW
1.90 kW apart
Max AC power
51.90 kW
55.50 kW
3.60 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
130.5 A
80.5 A
50.0 A apart
PV input
Max PV power
90.83 kW
75.00 kW
15.83 kW apart
DC/AC ratio
1.75
1.50
+0.25 for SE90K (for 220V/230V line-to-line grids)
Max DC voltage
600 V
1100 V
500 V apart
MPPT voltage range
370-600 V
200-1000 V
370-600 V vs 200-1000 V
Start voltage
-
250 V
Not published by SolarEdge
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
2
Not published by SolarEdge
Max input current per tracker
-
26.0 A
Not published by SolarEdge
Efficiency
European efficiency
98.0 %
98.4 %
+0.4 pp for MAX 50KTL3 LV
Max efficiency
98.3 %
98.8 %
+0.5 pp for MAX 50KTL3 LV
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
-
82.0 kg
Not published by SolarEdge
Weight per kW
-
1.6 kg/kW
Not published by SolarEdge
Dimensions
-
600x860x300 mm
Not published by SolarEdge
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
67 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
SolarEdge SE90K (for 220V/230V line-to-line grids) vs Huawei SUN2000-50KTL-JPM0
8 differences, the largest is rated ac power
Same type, similar size
Huawei
SolarEdge SE90K (for 220V/230V line-to-line grids) vs Huawei SUN2000-50KTL-M0
9 differences, the largest is rated ac power
Same type, similar size
Ginlong Solis
SolarEdge SE90K (for 220V/230V line-to-line grids) vs Solis-50K-HV
10 differences, the largest is rated ac power
Same type, similar size
Sungrow
Growatt MAX 50KTL3 LV vs Sungrow SG50CX
6 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.