SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4)
vs
SUN-7.5K-G
6 of 20 identical
Swap
Change inverters
SolarEdge SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Deye SUN-7.5K-G

SolarEdge
SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4)
7.2 kW
97.7 % euro
Grid-tie
VS
The verdict
SUN-7.5K-G leads on the differences that matter
The largest is rated ac power: 0.30 kW apart. 6 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
6
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 20 parameters
What actually differs
Parameter
SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4)
SUN-7.5K-G
Difference
Rated AC power
7.20 kW
7.50 kW
0.30 kW apart
Max DC voltage
600 V
550 V
50 V apart
Max AC power
7.20 kW
8.30 kW
1.10 kW apart
Weight
30.7 kg
11.0 kg
19.7 kg lighter
Weight per kW
4.3 kg/kW
1.5 kg/kW
2.8 kg/kW lighter
Noise
50 dB
25 dB
25 dB quieter
European efficiency
97.7 %
97.5 %
0.2 pp more efficient
Max efficiency
98.0 %
97.7 %
0.3 pp more efficient
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Max AC current
20.0 A
35.9 A
15.9 A apart
Max operating temperature
60 °C
65 °C
5 °C more heat tolerant
MPPT voltage range
370-600 V
70-550 V
370-600 V vs 70-550 V
Dimensions
540x315x260 mm
310x330x198 mm
540x315x260 mm vs 310x330x198 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4)
SUN-7.5K-G
Difference
AC output
Rated AC power
7.20 kW
7.50 kW
0.30 kW apart
Max AC power
7.20 kW
8.30 kW
1.10 kW apart
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
230 V
230 V
Same
Max AC current
20.0 A
35.9 A
15.9 A apart
PV input
Max PV power
9.72 kW
9.80 kW
Effectively the same
DC/AC ratio
1.35
1.31
Effectively the same
Max DC voltage
600 V
550 V
50 V apart
MPPT voltage range
370-600 V
70-550 V
370-600 V vs 70-550 V
Start voltage
-
120 V
Not published by SolarEdge
MPP trackers
-
2
Not published by SolarEdge
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
97.7 %
97.5 %
+0.2 pp for SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4)
Max efficiency
98.0 %
97.7 %
+0.3 pp for SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4)
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
30.7 kg
11.0 kg
-19.7 kg for SUN-7.5K-G
Weight per kW
4.3 kg/kW
1.5 kg/kW
-2.8 kg/kW for SUN-7.5K-G
Dimensions
540x315x260 mm
310x330x198 mm
540x315x260 mm vs 310x330x198 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
natural
forced-air vs natural
Noise
50 dB
25 dB
-25 dB for SUN-7.5K-G
Max operating temperature
60 °C
65 °C
+5 °C for SUN-7.5K-G
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
-
Yes
Not published by SolarEdge
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
SolarEdge SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Growatt MOD 7000TL3-X
15 differences, the largest is rated ac power
Same type, similar size
Growatt
SolarEdge SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Growatt MOD 7KTL3-X2(Pro)
15 differences, the largest is rated ac power
Same type, similar size
Sungrow
SolarEdge SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Sungrow SG5.0RT
12 differences, the largest is rated ac power
Same type, similar size
Fronius International
Deye SUN-7.5K-G vs Fronius Primo 7.6-1
14 differences, the largest is max dc voltage
Same type, similar size
Sofar Solar
Deye SUN-7.5K-G vs SOFAR 7.7KTLM-G3
13 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.