Skip to main content
SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) vs MOD 7KTL3-X2(Pro) 5 of 20 identical Swap Change inverters

SolarEdge SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Growatt MOD 7KTL3-X2(Pro)

SolarEdge SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4)
SolarEdge
SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4)
7.2 kW 97.7 % euro Grid-tie
VS
Growatt MOD 7KTL3-X2(Pro)
Growatt
MOD 7KTL3-X2(Pro)
7 kW 98.1 % euro Grid-tie
The verdict

MOD 7KTL3-X2(Pro) leads on the differences that matter

The largest is rated ac power: 0.20 kW apart. 5 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
5 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 20 parameters
Parameter SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) MOD 7KTL3-X2(Pro) Difference
Rated AC power 7.20 kW 7.00 kW 0.20 kW apart
Max DC voltage 600 V 1100 V 500 V apart
European efficiency 97.7 % 98.1 % 0.4 pp more efficient
Max efficiency 98.0 % 98.6 % 0.6 pp more efficient
Max AC power 7.20 kW 7.00 kW 0.20 kW apart
Max PV power 9.72 kW 10.50 kW 0.78 kW apart
Weight 30.7 kg 14.6 kg 16.1 kg lighter
Weight per kW 4.3 kg/kW 2.1 kg/kW 2.2 kg/kW lighter
DC/AC ratio 1.35 1.50 0.15 more oversizing headroom
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 20.0 A 11.7 A 8.3 A apart
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 370-600 V 140-1000 V 370-600 V vs 140-1000 V
Dimensions 540x315x260 mm 387x425x178 mm 540x315x260 mm vs 387x425x178 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) MOD 7KTL3-X2(Pro) Difference
AC output
Rated AC power 7.20 kW 7.00 kW 0.20 kW apart
Max AC power 7.20 kW 7.00 kW 0.20 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 20.0 A 11.7 A 8.3 A apart
PV input
Max PV power 9.72 kW 10.50 kW 0.78 kW apart
DC/AC ratio 1.35 1.50 +0.15 for MOD 7KTL3-X2(Pro)
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 370-600 V 140-1000 V 370-600 V vs 140-1000 V
Start voltage - 160 V Not published by SolarEdge
MPP trackers - 2 Not published by SolarEdge
Strings per tracker - 1 Not published by SolarEdge
Max input current per tracker - 20.0 A Not published by SolarEdge
Efficiency
European efficiency 97.7 % 98.1 % +0.4 pp for MOD 7KTL3-X2(Pro)
Max efficiency 98.0 % 98.6 % +0.6 pp for MOD 7KTL3-X2(Pro)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 30.7 kg 14.6 kg -16.1 kg for MOD 7KTL3-X2(Pro)
Weight per kW 4.3 kg/kW 2.1 kg/kW -2.2 kg/kW for MOD 7KTL3-X2(Pro)
Dimensions 540x315x260 mm 387x425x178 mm 540x315x260 mm vs 387x425x178 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air natural forced-air vs natural
Noise 50 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - 8 yrs Not published by SolarEdge
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
SolarEdge SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Growatt MOD 7000TL3-X
15 differences, the largest is rated ac power
Same type, similar size
Sungrow
SolarEdge SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Sungrow SG5.0RT
12 differences, the largest is rated ac power
Same type, similar size
Sungrow
SolarEdge SE12.5K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Sungrow SG7.0RT-P2
13 differences, the largest is rated ac power
Same type, similar size
Deye
Growatt MOD 7KTL3-X2(Pro) vs Deye SUN-7K-G03
15 differences, the largest is european efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.