Skip to main content
SE100K (for 220V/230V line-to-line grids) vs GW60KN-MT 6 of 14 identical Swap Change inverters

SolarEdge SE100K (for 220V/230V line-to-line grids) vs GoodWe GW60KN-MT

SolarEdge SE100K (for 220V/230V line-to-line grids)
SolarEdge
SE100K (for 220V/230V line-to-line grids)
57.7 kW 98.0 % euro Grid-tie
VS
GoodWe GW60KN-MT
GoodWe
GW60KN-MT
60 kW 98.5 % euro Grid-tie
The verdict

GW60KN-MT leads on the differences that matter

The largest is rated ac power: 2.30 kW apart. 6 of 14 comparable parameters are identical, with 18 more left out because at least one datasheet does not publish them.

See all 8 differences
How alike are they
6 of 14 comparable
parameters are identical
identical differs not published
01

What actually differs

8 of 14 parameters
Parameter SE100K (for 220V/230V line-to-line grids) GW60KN-MT Difference
Rated AC power 57.70 kW 60.00 kW 2.30 kW apart
European efficiency 98.0 % 98.5 % 0.5 pp more efficient
Max DC voltage 600 V 1100 V 500 V apart
Max AC power 57.70 kW 66.00 kW 8.30 kW apart
Max efficiency 98.3 % 98.8 % 0.5 pp more efficient
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 145.0 A 96.0 A 49.0 A apart
MPPT voltage range 370-600 V 200-1000 V 370-600 V vs 200-1000 V
02

Full specification

Parameter SE100K (for 220V/230V line-to-line grids) GW60KN-MT Difference
AC output
Rated AC power 57.70 kW 60.00 kW 2.30 kW apart
Max AC power 57.70 kW 66.00 kW 8.30 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 145.0 A 96.0 A 49.0 A apart
PV input
Max PV power 100.97 kW - Not published by GoodWe
DC/AC ratio 1.75 - Not published by GoodWe
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 370-600 V 200-1000 V 370-600 V vs 200-1000 V
Start voltage - 200 V Not published by SolarEdge
MPP trackers - 4 Not published by SolarEdge
Strings per tracker - 4 Not published by SolarEdge
Max input current per tracker - 44.0 A Not published by SolarEdge
Efficiency
European efficiency 98.0 % 98.5 % +0.5 pp for GW60KN-MT
Max efficiency 98.3 % 98.8 % +0.5 pp for GW60KN-MT
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight - 64.0 kg Not published by SolarEdge
Weight per kW - 1.1 kg/kW Not published by SolarEdge
Dimensions - 788x586x267 mm Not published by SolarEdge
Ingress protection IP65 IP65 Same
Cooling forced-air forced-air Same
Noise 67 dB - Not published by GoodWe
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by GoodWe
Arc fault protection Yes - Not published by GoodWe
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
SolarEdge SE100K (for 220V/230V line-to-line grids) vs Huawei SUN2000-60KTL-M0
9 differences, the largest is rated ac power
Same type, similar size
Sungrow
SolarEdge SE100K (for 220V/230V line-to-line grids) vs Sungrow SG60KTL-182
8 differences, the largest is rated ac power
Same type, similar size
Ginlong Solis
SolarEdge SE100K (for 220V/230V line-to-line grids) vs Solis-60K-4G
10 differences, the largest is rated ac power
Same type, similar size
Growatt
GoodWe GW60KN-MT vs Growatt MAX 60KTL3 LV
8 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.