Skip to main content
HYD 6000-EP vs SUN2000-6KTL-M1 10 of 26 identical Swap Change inverters

Sofar Solar HYD 6000-EP vs Huawei SUN2000-6KTL-M1

Sofar Solar
HYD 6000-EP
6 kW 94.6 % euro Hybrid
VS
Huawei SUN2000-6KTL-M1
Huawei
SUN2000-6KTL-M1
6 kW 97.7 % euro Hybrid
The verdict

SUN2000-6KTL-M1 leads on the differences that matter

The largest is european efficiency: 3.1 pp more efficient. 10 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
10 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 26 parameters
Parameter HYD 6000-EP SUN2000-6KTL-M1 Difference
European efficiency 94.6 % 97.7 % 3.1 pp more efficient
Max DC voltage 600 V 1100 V 500 V apart
Max input current per tracker 13.0 A 11.0 A 2.0 A more headroom
Max efficiency 98.0 % 98.6 % 0.6 pp more efficient
Max AC power 6.00 kW 6.60 kW 0.60 kW apart
Max charge current 100 A 16 A 84 A faster charging
Weight 21.5 kg 17.0 kg 4.5 kg lighter
Weight per kW 3.6 kg/kW 2.8 kg/kW 0.8 kg/kW lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 26.1 A 10.1 A 16.0 A apart
Start voltage 100 V 200 V 100 V earlier start
MPP trackers 1 2 1 tracker more
MPPT voltage range 90-550 V 140-980 V 90-550 V vs 140-980 V
Battery voltage 42-58 Vdc 600 V ~ 980 V 42-58 Vdc vs 600 V ~ 980 V
Dimensions 503x482x183 mm 525x470x146 mm 503x482x183 mm vs 525x470x146 mm
02

Full specification

Parameter HYD 6000-EP SUN2000-6KTL-M1 Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.00 kW 6.60 kW 0.60 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 26.1 A 10.1 A 16.0 A apart
PV input
Max PV power 9.00 kW 9.00 kW Same
DC/AC ratio 1.50 1.50 Same
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 90-550 V 140-980 V 90-550 V vs 140-980 V
Start voltage 100 V 200 V -100 V for HYD 6000-EP
MPP trackers 1 2 +1 trackers for SUN2000-6KTL-M1
Strings per tracker 1 1 Same
Max input current per tracker 13.0 A 11.0 A +2.0 A for HYD 6000-EP
Efficiency
European efficiency 94.6 % 97.7 % +3.1 pp for SUN2000-6KTL-M1
Max efficiency 98.0 % 98.6 % +0.6 pp for SUN2000-6KTL-M1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 42-58 Vdc 600 V ~ 980 V 42-58 Vdc vs 600 V ~ 980 V
Max charge current 100 A 16 A +84 A for HYD 6000-EP
Backup power - 3.3 kW Not published by Sofar Solar
Physical
Weight 21.5 kg 17.0 kg -4.5 kg for SUN2000-6KTL-M1
Weight per kW 3.6 kg/kW 2.8 kg/kW -0.8 kg/kW for SUN2000-6KTL-M1
Dimensions 503x482x183 mm 525x470x146 mm 503x482x183 mm vs 525x470x146 mm
Ingress protection IP65 IP65 Same
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Sofar Solar
Arc fault protection - Yes Not published by Sofar Solar
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Sofar Solar HYD 6000-EP vs SolarEdge SE6000H
9 differences, the largest is european efficiency
Same type, similar size
Growatt
Sofar Solar HYD 6000-EP vs Growatt MOD 6000TL3-HU
19 differences, the largest is european efficiency
Same type, similar size
Huawei
Sofar Solar HYD 6000-EP vs Huawei SUN2000-6KTL-L1
11 differences, the largest is european efficiency