Skip to main content
HYD 6000-EP vs MOD 6000TL3-HU 7 of 26 identical Swap Change inverters

Sofar Solar HYD 6000-EP vs Growatt MOD 6000TL3-HU

Sofar Solar
HYD 6000-EP
6 kW 94.6 % euro Hybrid
VS
Growatt MOD 6000TL3-HU
Growatt
MOD 6000TL3-HU
6 kW 97.8 % euro Hybrid
The verdict

MOD 6000TL3-HU leads on the differences that matter

The largest is european efficiency: 3.2 pp more efficient. 7 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 19 differences
How alike are they
7 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

19 of 26 parameters
Parameter HYD 6000-EP MOD 6000TL3-HU Difference
European efficiency 94.6 % 97.8 % 3.2 pp more efficient
Max DC voltage 600 V 1000 V 400 V apart
Max input current per tracker 13.0 A 20.0 A 7.0 A more headroom
Max AC power 6.00 kW 6.60 kW 0.60 kW apart
Max PV power 9.00 kW 12.00 kW 3.00 kW apart
DC/AC ratio 1.50 2.00 0.50 more oversizing headroom
Max charge current 100 A 25 A 75 A faster charging
Weight 21.5 kg 19.0 kg 2.5 kg lighter
Max efficiency 98.0 % 98.3 % 0.3 pp more efficient
Weight per kW 3.6 kg/kW 3.2 kg/kW 0.4 kg/kW lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 26.1 A 10.0 A 16.1 A apart
Start voltage 100 V 180 V 80 V earlier start
MPP trackers 1 2 1 tracker more
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 90-550 V 140-1000 V 90-550 V vs 140-1000 V
Battery voltage 42-58 Vdc 600-980 V 42-58 Vdc vs 600-980 V
Dimensions 503x482x183 mm 468x408x202 mm 503x482x183 mm vs 468x408x202 mm
02

Full specification

Parameter HYD 6000-EP MOD 6000TL3-HU Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.00 kW 6.60 kW 0.60 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 26.1 A 10.0 A 16.1 A apart
PV input
Max PV power 9.00 kW 12.00 kW 3.00 kW apart
DC/AC ratio 1.50 2.00 +0.50 for MOD 6000TL3-HU
Max DC voltage 600 V 1000 V 400 V apart
MPPT voltage range 90-550 V 140-1000 V 90-550 V vs 140-1000 V
Start voltage 100 V 180 V -80 V for HYD 6000-EP
MPP trackers 1 2 +1 trackers for MOD 6000TL3-HU
Strings per tracker 1 1 Same
Max input current per tracker 13.0 A 20.0 A +7.0 A for MOD 6000TL3-HU
Efficiency
European efficiency 94.6 % 97.8 % +3.2 pp for MOD 6000TL3-HU
Max efficiency 98.0 % 98.3 % +0.3 pp for MOD 6000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 42-58 Vdc 600-980 V 42-58 Vdc vs 600-980 V
Max charge current 100 A 25 A +75 A for HYD 6000-EP
Backup power - - Neither datasheet publishes this
Physical
Weight 21.5 kg 19.0 kg -2.5 kg for MOD 6000TL3-HU
Weight per kW 3.6 kg/kW 3.2 kg/kW -0.4 kg/kW for MOD 6000TL3-HU
Dimensions 503x482x183 mm 468x408x202 mm 503x482x183 mm vs 468x408x202 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - 29 dB Not published by Sofar Solar
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Sofar Solar
Integrated DC switch Yes Yes Same
Warranty
Warranty - 10 yrs Not published by Sofar Solar
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Sofar Solar HYD 6000-EP vs SolarEdge SE6000H
9 differences, the largest is european efficiency
Same type, similar size
Huawei
Sofar Solar HYD 6000-EP vs Huawei SUN2000-6KTL-L1
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Sofar Solar HYD 6000-EP vs Huawei SUN2000-6KTL-M1
16 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 6000TL3-HU vs Huawei SUN2000-6KTL-M1 (High current version)
13 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.