SMA Solar Sunny Tripower X 50 (STP 50-80) vs Solis-50K-HV

SMA Solar
Sunny Tripower X 50 (STP 50-80)
50 kW
97.7 % euro
Grid-tie
VS
The verdict
Solis-50K-HV leads on the differences that matter
The largest is european efficiency: 0.8 pp more efficient. 9 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
9
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 20 parameters
What actually differs
Parameter
Sunny Tripower X 50 (STP 50-80)
Solis-50K-HV
Difference
European efficiency
97.7 %
98.5 %
0.8 pp more efficient
Max efficiency
98.1 %
99.0 %
0.9 pp more efficient
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Max PV power
75.00 kW
60.00 kW
15.00 kW apart
DC/AC ratio
1.50
1.20
0.30 more oversizing headroom
Weight
50.5 kg
61.0 kg
10.5 kg lighter
Max AC current
79.5 A
66.2 A
13.3 A apart
Start voltage
250 V
200 V
50 V earlier start
MPP trackers
5
4
1 tracker more
Weight per kW
1.0 kg/kW
1.2 kg/kW
0.2 kg/kW lighter
Dimensions
718x680x332 mm
700x630x357 mm
718x680x332 mm vs 700x630x357 mm
02
Full specification
Parameter
Sunny Tripower X 50 (STP 50-80)
Solis-50K-HV
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
79.5 A
66.2 A
13.3 A apart
PV input
Max PV power
75.00 kW
60.00 kW
15.00 kW apart
DC/AC ratio
1.50
1.20
+0.30 for Sunny Tripower X 50 (STP 50-80)
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
200-1000 V
Same
Start voltage
250 V
200 V
-50 V for Solis-50K-HV
MPP trackers
5
4
+1 trackers for Sunny Tripower X 50 (STP 50-80)
Strings per tracker
2
-
Not published by Ginlong Solis
Max input current per tracker
40.0 A
-
Not published by Ginlong Solis
Efficiency
European efficiency
97.7 %
98.5 %
+0.8 pp for Solis-50K-HV
Max efficiency
98.1 %
99.0 %
+0.9 pp for Solis-50K-HV
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
50.5 kg
61.0 kg
-10.5 kg for Sunny Tripower X 50 (STP 50-80)
Weight per kW
1.0 kg/kW
1.2 kg/kW
-0.2 kg/kW for Sunny Tripower X 50 (STP 50-80)
Dimensions
718x680x332 mm
700x630x357 mm
718x680x332 mm vs 700x630x357 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
-
Not published by Ginlong Solis
Noise
63 dB
-
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Ginlong Solis
Arc fault protection
Yes
-
Not published by Ginlong Solis
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
SMA Solar Sunny Tripower X 50 (STP 50-80) vs Huawei SUN2000-50KTL-JPM0
11 differences, the largest is european efficiency
Same type, similar size
Huawei
SMA Solar Sunny Tripower X 50 (STP 50-80) vs Huawei SUN2000-50KTL-M0
10 differences, the largest is european efficiency
Same type, similar size
Growatt
SMA Solar Sunny Tripower X 50 (STP 50-80) vs Growatt MAX 50KTL3 LV
8 differences, the largest is european efficiency
Same type, similar size
Sungrow
Solis-50K-HV vs Sungrow SG50CX
6 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.