Solis-50K-HV vs SMA Solar Sunny Tripower X 50 (STP 50-80)
VS

SMA Solar
Sunny Tripower X 50 (STP 50-80)
50 kW
97.7 % euro
Grid-tie
The verdict
Solis-50K-HV leads on the differences that matter
The largest is european efficiency: 0.8 pp more efficient. 9 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
9
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 20 parameters
What actually differs
Parameter
Solis-50K-HV
Sunny Tripower X 50 (STP 50-80)
Difference
European efficiency
98.5 %
97.7 %
0.8 pp more efficient
Max efficiency
99.0 %
98.1 %
0.9 pp more efficient
Max AC power
55.00 kW
50.00 kW
5.00 kW apart
Max PV power
60.00 kW
75.00 kW
15.00 kW apart
DC/AC ratio
1.20
1.50
0.30 more oversizing headroom
Weight
61.0 kg
50.5 kg
10.5 kg lighter
Max AC current
66.2 A
79.5 A
13.3 A apart
Start voltage
200 V
250 V
50 V earlier start
MPP trackers
4
5
1 tracker more
Weight per kW
1.2 kg/kW
1.0 kg/kW
0.2 kg/kW lighter
Dimensions
700x630x357 mm
718x680x332 mm
700x630x357 mm vs 718x680x332 mm
02
Full specification
Parameter
Solis-50K-HV
Sunny Tripower X 50 (STP 50-80)
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
55.00 kW
50.00 kW
5.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
66.2 A
79.5 A
13.3 A apart
PV input
Max PV power
60.00 kW
75.00 kW
15.00 kW apart
DC/AC ratio
1.20
1.50
+0.30 for Sunny Tripower X 50 (STP 50-80)
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
200-1000 V
Same
Start voltage
200 V
250 V
-50 V for Solis-50K-HV
MPP trackers
4
5
+1 trackers for Sunny Tripower X 50 (STP 50-80)
Strings per tracker
-
2
Not published by Ginlong Solis
Max input current per tracker
-
40.0 A
Not published by Ginlong Solis
Efficiency
European efficiency
98.5 %
97.7 %
+0.8 pp for Solis-50K-HV
Max efficiency
99.0 %
98.1 %
+0.9 pp for Solis-50K-HV
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
61.0 kg
50.5 kg
-10.5 kg for Sunny Tripower X 50 (STP 50-80)
Weight per kW
1.2 kg/kW
1.0 kg/kW
-0.2 kg/kW for Sunny Tripower X 50 (STP 50-80)
Dimensions
700x630x357 mm
718x680x332 mm
700x630x357 mm vs 718x680x332 mm
Ingress protection
IP65
IP65
Same
Cooling
-
forced-air
Not published by Ginlong Solis
Noise
-
63 dB
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
-
Yes
Not published by Ginlong Solis
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Solis-50K-HV vs Huawei SUN2000-50KTL-JPM0
6 differences, the largest is max ac power
Same type, similar size
Huawei
Solis-50K-HV vs Huawei SUN2000-50KTL-M0
6 differences, the largest is mpp trackers
Same type, similar size
Growatt
Solis-50K-HV vs Growatt MAX 50KTL3 LV
9 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.