PowMr POW-HVM4.5K-24V vs Growatt SPF 4000T DVM
VS
The verdict
POW-HVM4.5K-24V leads on the differences that matter
The largest is rated ac power: 0.50 kW apart. 3 of 10 comparable parameters are identical, with 22 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
3
of 10 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 10 parameters
What actually differs
Parameter
POW-HVM4.5K-24V
SPF 4000T DVM
Difference
Rated AC power
4.50 kW
4.00 kW
0.50 kW apart
Max AC power
4.50 kW
4.00 kW
0.50 kW apart
Max PV power
6.00 kW
5.00 kW
1.00 kW apart
Weight
7.5 kg
42.0 kg
34.5 kg lighter
Weight per kW
1.7 kg/kW
10.5 kg/kW
8.8 kg/kW lighter
DC/AC ratio
1.33
1.25
0.08 more oversizing headroom
Dimensions
318x468x159 mm
540x360x218 mm
318x468x159 mm vs 540x360x218 mm
02
Full specification
Parameter
POW-HVM4.5K-24V
SPF 4000T DVM
Difference
AC output
Rated AC power
4.50 kW
4.00 kW
0.50 kW apart
Max AC power
4.50 kW
4.00 kW
0.50 kW apart
Grid connection
-
Single-phase
Not published by PowMr
Nominal AC voltage
-
240 V
Not published by PowMr
Max AC current
-
-
Neither datasheet publishes this
PV input
Max PV power
6.00 kW
5.00 kW
1.00 kW apart
DC/AC ratio
1.33
1.25
+0.08 for POW-HVM4.5K-24V
Max DC voltage
-
150 V
Not published by PowMr
MPPT voltage range
-
60-145 V
Not published by PowMr
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
98.0 %
98.0 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
-
48VDC
Not published by PowMr
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
7.5 kg
42.0 kg
-34.5 kg for POW-HVM4.5K-24V
Weight per kW
1.7 kg/kW
10.5 kg/kW
-8.8 kg/kW for POW-HVM4.5K-24V
Dimensions
318x468x159 mm
540x360x218 mm
318x468x159 mm vs 540x360x218 mm
Ingress protection
-
IP20
Not published by PowMr
Cooling
-
-
Neither datasheet publishes this
Noise
-
-
Neither datasheet publishes this
Max operating temperature
-
45 °C
Not published by PowMr
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SMA Solar
PowMr POW-HVM4.5K-24V vs SMA Solar SI6.0H-13
6 differences, the largest is max efficiency
Same type, similar size
PowMr
PowMr POW-HVM4.5K-24V vs PowMr POW-HVM4.2M-24V-N
6 differences, the largest is rated ac power
Same type, similar size
Growatt
PowMr POW-HVM4.5K-24V vs Growatt SPF 5000 ES
7 differences, the largest is rated ac power
Same type, similar size
Growatt
Growatt SPF 4000T DVM vs Growatt SPF 4000T DVM-MPV
3 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPF 4000T DVM vs Growatt SPF 4000TL HVM
10 differences, the largest is max efficiency
Same type, similar size
Ginlong Solis
Growatt SPF 4000T DVM vs Ginlong Solis S6-EO1P4K-48
12 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.