Growatt WT 40K-H-US L2 / WT 40K-HU-US L2 vs GoodWe GW40K-ET-10
VS
The verdict
GW40K-ET-10 leads on the differences that matter
The largest is max dc voltage: 200 V apart. 7 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
7
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 20 parameters
What actually differs
Parameter
WT 40K-H-US L2 / WT 40K-HU-US L2
GW40K-ET-10
Difference
Max DC voltage
800 V
1000 V
200 V apart
Max input current per tracker
32.0 A
42.0 A
10.0 A more headroom
Max AC power
40.00 kW
44.00 kW
4.00 kW apart
Max PV power
86.40 kW
60.00 kW
26.40 kW apart
DC/AC ratio
2.16
1.50
0.66 more oversizing headroom
Weight
140.0 kg
62.0 kg
78.0 kg lighter
Weight per kW
3.5 kg/kW
1.6 kg/kW
1.9 kg/kW lighter
Nominal AC voltage
208 V
380 V
172 V apart
Max AC current
122.2 A
66.7 A
55.5 A apart
Start voltage
195 V
160 V
35 V earlier start
MPPT voltage range
180-600 V
165-850 V
180-600 V vs 165-850 V
Battery voltage
380-650V
200-800 V
380-650V vs 200-800 V
Dimensions
1350x820x501 mm
660x520x260 mm
1350x820x501 mm vs 660x520x260 mm
02
Full specification
Parameter
WT 40K-H-US L2 / WT 40K-HU-US L2
GW40K-ET-10
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
40.00 kW
44.00 kW
4.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
208 V
380 V
172 V apart
Max AC current
122.2 A
66.7 A
55.5 A apart
PV input
Max PV power
86.40 kW
60.00 kW
26.40 kW apart
DC/AC ratio
2.16
1.50
+0.66 for WT 40K-H-US L2 / WT 40K-HU-US L2
Max DC voltage
800 V
1000 V
200 V apart
MPPT voltage range
180-600 V
165-850 V
180-600 V vs 165-850 V
Start voltage
195 V
160 V
-35 V for GW40K-ET-10
MPP trackers
2
-
Not published by GoodWe
Strings per tracker
-
2
Not published by Growatt
Max input current per tracker
32.0 A
42.0 A
+10.0 A for GW40K-ET-10
Efficiency
European efficiency
-
97.8 %
Not published by Growatt
Max efficiency
98.0 %
98.1 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
380-650V
200-800 V
380-650V vs 200-800 V
Max charge current
-
100 A
Not published by Growatt
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
140.0 kg
62.0 kg
-78.0 kg for GW40K-ET-10
Weight per kW
3.5 kg/kW
1.6 kg/kW
-1.9 kg/kW for GW40K-ET-10
Dimensions
1350x820x501 mm
660x520x260 mm
1350x820x501 mm vs 660x520x260 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Growatt
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Growatt WT 40K-H-US L2 / WT 40K-HU-US L2 vs Ginlong Solis S6-EH3P40K-H
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt WT 40K-H-US L2 / WT 40K-HU-US L2 vs Growatt MID 40K-HU
13 differences, the largest is max dc voltage
Same type, similar size
Deye
Growatt WT 40K-H-US L2 / WT 40K-HU-US L2 vs Deye SUN-40K-SG01HP3-EU-BM4
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.