Growatt WT 40K-H-US L2 / WT 40K-HU-US L2 vs Ginlong Solis S6-EH3P40K-H
VS
The verdict
S6-EH3P40K-H leads on the differences that matter
The largest is max dc voltage: 200 V apart. 7 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
7
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 20 parameters
What actually differs
Parameter
WT 40K-H-US L2 / WT 40K-HU-US L2
S6-EH3P40K-H
Difference
Max DC voltage
800 V
1000 V
200 V apart
Max input current per tracker
32.0 A
40.0 A
8.0 A more headroom
Max PV power
86.40 kW
80.00 kW
6.40 kW apart
Weight
140.0 kg
73.0 kg
67.0 kg lighter
Weight per kW
3.5 kg/kW
1.8 kg/kW
1.7 kg/kW lighter
DC/AC ratio
2.16
2.00
0.16 more oversizing headroom
Nominal AC voltage
208 V
400 V
192 V apart
Max AC current
122.2 A
60.8 A
61.4 A apart
Max efficiency
98.0 %
97.8 %
0.2 pp more efficient
MPPT voltage range
180-600 V
150-850 V
180-600 V vs 150-850 V
Battery voltage
380-650V
150-800 V
380-650V vs 150-800 V
Start voltage
195 V
180 V
15 V earlier start
Dimensions
1350x820x501 mm
880x530x290 mm
1350x820x501 mm vs 880x530x290 mm
02
Full specification
Parameter
WT 40K-H-US L2 / WT 40K-HU-US L2
S6-EH3P40K-H
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
40.00 kW
40.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
208 V
400 V
192 V apart
Max AC current
122.2 A
60.8 A
61.4 A apart
PV input
Max PV power
86.40 kW
80.00 kW
6.40 kW apart
DC/AC ratio
2.16
2.00
+0.16 for WT 40K-H-US L2 / WT 40K-HU-US L2
Max DC voltage
800 V
1000 V
200 V apart
MPPT voltage range
180-600 V
150-850 V
180-600 V vs 150-850 V
Start voltage
195 V
180 V
-15 V for S6-EH3P40K-H
MPP trackers
2
-
Not published by Ginlong Solis
Strings per tracker
-
2
Not published by Growatt
Max input current per tracker
32.0 A
40.0 A
+8.0 A for S6-EH3P40K-H
Efficiency
European efficiency
-
97.4 %
Not published by Growatt
Max efficiency
98.0 %
97.8 %
+0.2 pp for WT 40K-H-US L2 / WT 40K-HU-US L2
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
380-650V
150-800 V
380-650V vs 150-800 V
Max charge current
-
140 A
Not published by Growatt
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
140.0 kg
73.0 kg
-67.0 kg for S6-EH3P40K-H
Weight per kW
3.5 kg/kW
1.8 kg/kW
-1.7 kg/kW for S6-EH3P40K-H
Dimensions
1350x820x501 mm
880x530x290 mm
1350x820x501 mm vs 880x530x290 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Growatt WT 40K-H-US L2 / WT 40K-HU-US L2 vs GoodWe GW40K-ET-10
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt WT 40K-H-US L2 / WT 40K-HU-US L2 vs Growatt MID 40K-HU
13 differences, the largest is max dc voltage
Same type, similar size
Deye
Growatt WT 40K-H-US L2 / WT 40K-HU-US L2 vs Deye SUN-40K-SG01HP3-EU-BM4
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.

