Growatt WIT 50K-AU vs Growatt MID 50K-HU
VS
The verdict
MID 50K-HU leads on the differences that matter
The largest is weight: 70.0 kg lighter. 10 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 6 differencesHow alike are they
10
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
6 of 16 parameters
What actually differs
Parameter
WIT 50K-AU
MID 50K-HU
Difference
Weight
120.0 kg
50.0 kg
70.0 kg lighter
Weight per kW
2.4 kg/kW
1.0 kg/kW
1.4 kg/kW lighter
Max AC current
83.3 A
75.8 A
7.5 A apart
Start voltage
768 V
160 V
608 V earlier start
Battery voltage
600-1000V (for 3P3W); 680-1000V (for 3P4W); recovery start: 768V
600-980 V
600-1000V (for 3P3W); 680-1000V (for 3P4W); recovery start: 768V vs 600-980 V
Dimensions
1350x820x510 mm
570x680x256 mm
1350x820x510 mm vs 570x680x256 mm
02
Full specification
Parameter
WIT 50K-AU
MID 50K-HU
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
50.00 kW
50.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
83.3 A
75.8 A
7.5 A apart
PV input
Max PV power
-
100.00 kW
Not published by Growatt
DC/AC ratio
-
2.00
Not published by Growatt
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
-
200-1000 V
Not published by Growatt
Start voltage
768 V
160 V
-608 V for MID 50K-HU
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
2
Not published by Growatt
Max input current per tracker
-
40.0 A
Not published by Growatt
Efficiency
European efficiency
-
97.2 %
Not published by Growatt
Max efficiency
-
98.6 %
Not published by Growatt
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-1000V (for 3P3W); 680-1000V (for 3P4W); recovery start: 768V
600-980 V
600-1000V (for 3P3W); 680-1000V (for 3P4W); recovery start: 768V vs 600-980 V
Max charge current
-
42 A
Not published by Growatt
Backup power
-
30.0 kW
Not published by Growatt
Physical
Weight
120.0 kg
50.0 kg
-70.0 kg for MID 50K-HU
Weight per kW
2.4 kg/kW
1.0 kg/kW
-1.4 kg/kW for MID 50K-HU
Dimensions
1350x820x510 mm
570x680x256 mm
1350x820x510 mm vs 570x680x256 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
55 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
-
5 yrs
Not published by Growatt
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Growatt WIT 50K-AU vs GoodWe GW50K-ET-10
7 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Growatt WIT 50K-AU vs Ginlong Solis S6-EH3P50K-H
6 differences, the largest is weight
Same type, similar size
Deye
Growatt WIT 50K-AU vs Deye SUN-50K-SG01HP3-EU-BM4
7 differences, the largest is max ac power
Same type, similar size
Growatt
Growatt MID 50K-HU vs Growatt WIT 50K-A-US / WIT 50K-AU-US
7 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.

