Growatt SPM 8000TL-HU vs Growatt MOD 8000TL3-XH
VS
The verdict
MOD 8000TL3-XH leads on the differences that matter
The largest is european efficiency: 1.6 pp more efficient. 9 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.
See all 17 differencesHow alike are they
9
of 26 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
17 of 26 parameters
What actually differs
Parameter
SPM 8000TL-HU
MOD 8000TL3-XH
Difference
European efficiency
96.5 %
98.1 %
1.6 pp more efficient
Warranty
10 yrs
5 yrs
5 yrs longer
Max DC voltage
600 V
1100 V
500 V apart
Max efficiency
97.5 %
98.6 %
1.1 pp more efficient
Max AC power
8.00 kW
8.80 kW
0.80 kW apart
Weight
48.8 kg
14.0 kg
34.8 kg lighter
Weight per kW
6.1 kg/kW
1.8 kg/kW
4.4 kg/kW lighter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
40.0 A
13.3 A
26.7 A apart
Start voltage
120 V
160 V
40 V earlier start
MPP trackers
3
2
1 tracker more
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
150-500 V
140-1000 V
150-500 V vs 140-1000 V
Battery voltage
40-60 V
600-950 V
40-60 V vs 600-950 V
Dimensions
883x440x256 mm
387x425x178 mm
883x440x256 mm vs 387x425x178 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
SPM 8000TL-HU
MOD 8000TL3-XH
Difference
AC output
Rated AC power
8.00 kW
8.00 kW
Same
Max AC power
8.00 kW
8.80 kW
0.80 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
40.0 A
13.3 A
26.7 A apart
PV input
Max PV power
16.00 kW
16.00 kW
Same
DC/AC ratio
2.00
2.00
Same
Max DC voltage
600 V
1100 V
500 V apart
MPPT voltage range
150-500 V
140-1000 V
150-500 V vs 140-1000 V
Start voltage
120 V
160 V
-40 V for SPM 8000TL-HU
MPP trackers
3
2
+1 trackers for SPM 8000TL-HU
Strings per tracker
1
1
Same
Max input current per tracker
-
16.0 A
Not published by Growatt
Efficiency
European efficiency
96.5 %
98.1 %
+1.6 pp for MOD 8000TL3-XH
Max efficiency
97.5 %
98.6 %
+1.1 pp for MOD 8000TL3-XH
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
40-60 V
600-950 V
40-60 V vs 600-950 V
Max charge current
200 A
-
Not published by Growatt
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
48.8 kg
14.0 kg
-34.8 kg for MOD 8000TL3-XH
Weight per kW
6.1 kg/kW
1.8 kg/kW
-4.4 kg/kW for MOD 8000TL3-XH
Dimensions
883x440x256 mm
387x425x178 mm
883x440x256 mm vs 387x425x178 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
natural
forced-air vs natural
Noise
30 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
10 yrs
5 yrs
+5 yrs for SPM 8000TL-HU
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt SPM 8000TL-HU vs SolarEdge SE8000H
8 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPM 8000TL-HU vs Growatt MOD 8000TL3-HU
17 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt SPM 8000TL-HU vs Huawei SUN5000-8K-MAP0
19 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 8000TL3-XH vs Huawei SUN2000-8KTL-M1
10 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.