Skip to main content
MOD 8000TL3-XH vs SPM 8000TL-HU 9 of 26 identical Swap Change inverters

Growatt MOD 8000TL3-XH vs Growatt SPM 8000TL-HU

Growatt MOD 8000TL3-XH
Growatt
MOD 8000TL3-XH
8 kW 98.1 % euro Hybrid
VS
Growatt SPM 8000TL-HU
Growatt
SPM 8000TL-HU
8 kW 96.5 % euro Hybrid
The verdict

MOD 8000TL3-XH leads on the differences that matter

The largest is european efficiency: 1.6 pp more efficient. 9 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
9 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 26 parameters
Parameter MOD 8000TL3-XH SPM 8000TL-HU Difference
European efficiency 98.1 % 96.5 % 1.6 pp more efficient
Warranty 5 yrs 10 yrs 5 yrs longer
Max DC voltage 1100 V 600 V 500 V apart
Max efficiency 98.6 % 97.5 % 1.1 pp more efficient
Max AC power 8.80 kW 8.00 kW 0.80 kW apart
Weight 14.0 kg 48.8 kg 34.8 kg lighter
Weight per kW 1.8 kg/kW 6.1 kg/kW 4.4 kg/kW lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 13.3 A 40.0 A 26.7 A apart
Start voltage 160 V 120 V 40 V earlier start
MPP trackers 2 3 1 tracker more
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 150-500 V 140-1000 V vs 150-500 V
Battery voltage 600-950 V 40-60 V 600-950 V vs 40-60 V
Dimensions 387x425x178 mm 883x440x256 mm 387x425x178 mm vs 883x440x256 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MOD 8000TL3-XH SPM 8000TL-HU Difference
AC output
Rated AC power 8.00 kW 8.00 kW Same
Max AC power 8.80 kW 8.00 kW 0.80 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 13.3 A 40.0 A 26.7 A apart
PV input
Max PV power 16.00 kW 16.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 1100 V 600 V 500 V apart
MPPT voltage range 140-1000 V 150-500 V 140-1000 V vs 150-500 V
Start voltage 160 V 120 V -40 V for SPM 8000TL-HU
MPP trackers 2 3 +1 trackers for SPM 8000TL-HU
Strings per tracker 1 1 Same
Max input current per tracker 16.0 A - Not published by Growatt
Efficiency
European efficiency 98.1 % 96.5 % +1.6 pp for MOD 8000TL3-XH
Max efficiency 98.6 % 97.5 % +1.1 pp for MOD 8000TL3-XH
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-950 V 40-60 V 600-950 V vs 40-60 V
Max charge current - 200 A Not published by Growatt
Backup power - - Neither datasheet publishes this
Physical
Weight 14.0 kg 48.8 kg -34.8 kg for MOD 8000TL3-XH
Weight per kW 1.8 kg/kW 6.1 kg/kW -4.4 kg/kW for MOD 8000TL3-XH
Dimensions 387x425x178 mm 883x440x256 mm 387x425x178 mm vs 883x440x256 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural forced-air natural vs forced-air
Noise - 30 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection - Yes Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 10 yrs +5 yrs for SPM 8000TL-HU
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 8000TL3-XH vs SolarEdge SE8000H
11 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 8000TL3-XH vs Growatt MOD 8000TL3-HU
8 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 8000TL3-XH vs Huawei SUN5000-8K-MAP0
7 differences, the largest is max pv power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.