Skip to main content
SPM 10000TL-HU vs SUN2000-10KTL-M1 9 of 27 identical Swap Change inverters

Growatt SPM 10000TL-HU vs Huawei SUN2000-10KTL-M1

Growatt SPM 10000TL-HU
Growatt
SPM 10000TL-HU
9.999 kW 96.5 % euro Hybrid
VS
Huawei SUN2000-10KTL-M1
Huawei
SUN2000-10KTL-M1
10 kW 98.1 % euro Hybrid
The verdict

SUN2000-10KTL-M1 leads on the differences that matter

The largest is european efficiency: 1.6 pp more efficient. 9 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.

See all 18 differences
How alike are they
9 of 27 comparable
parameters are identical
identical differs not published
01

What actually differs

18 of 27 parameters
Parameter SPM 10000TL-HU SUN2000-10KTL-M1 Difference
European efficiency 96.5 % 98.1 % 1.6 pp more efficient
Max DC voltage 600 V 1100 V 500 V apart
Max efficiency 97.5 % 98.6 % 1.1 pp more efficient
Max AC power 10.00 kW 11.00 kW 1.00 kW apart
Max PV power 20.00 kW 15.00 kW 5.00 kW apart
DC/AC ratio 2.00 1.50 0.50 more oversizing headroom
Max charge current 200 A 16 A 184 A faster charging
Weight 48.8 kg 17.0 kg 31.8 kg lighter
Weight per kW 4.9 kg/kW 1.7 kg/kW 3.2 kg/kW lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 50.0 A 16.9 A 33.1 A apart
Start voltage 120 V 200 V 80 V earlier start
MPP trackers 3 2 1 tracker more
MPPT voltage range 150-500 V 140-980 V 150-500 V vs 140-980 V
Battery voltage 40-60 V 600 V ~ 980 V 40-60 V vs 600 V ~ 980 V
Dimensions 883x440x256 mm 525x470x146 mm 883x440x256 mm vs 525x470x146 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter SPM 10000TL-HU SUN2000-10KTL-M1 Difference
AC output
Rated AC power 10.00 kW 10.00 kW Same
Max AC power 10.00 kW 11.00 kW 1.00 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 50.0 A 16.9 A 33.1 A apart
PV input
Max PV power 20.00 kW 15.00 kW 5.00 kW apart
DC/AC ratio 2.00 1.50 +0.50 for SPM 10000TL-HU
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 150-500 V 140-980 V 150-500 V vs 140-980 V
Start voltage 120 V 200 V -80 V for SPM 10000TL-HU
MPP trackers 3 2 +1 trackers for SPM 10000TL-HU
Strings per tracker 1 1 Same
Max input current per tracker - 11.0 A Not published by Growatt
Efficiency
European efficiency 96.5 % 98.1 % +1.6 pp for SUN2000-10KTL-M1
Max efficiency 97.5 % 98.6 % +1.1 pp for SUN2000-10KTL-M1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 40-60 V 600 V ~ 980 V 40-60 V vs 600 V ~ 980 V
Max charge current 200 A 16 A +184 A for SPM 10000TL-HU
Backup power - 3.3 kW Not published by Growatt
Physical
Weight 48.8 kg 17.0 kg -31.8 kg for SUN2000-10KTL-M1
Weight per kW 4.9 kg/kW 1.7 kg/kW -3.2 kg/kW for SUN2000-10KTL-M1
Dimensions 883x440x256 mm 525x470x146 mm 883x440x256 mm vs 525x470x146 mm
Ingress protection IP65 IP65 Same
Cooling forced-air natural forced-air vs natural
Noise 30 dB - Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty 10 yrs - Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt SPM 10000TL-HU vs SolarEdge SE10000H
8 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPM 10000TL-HU vs Growatt MOD 10KTL3-XH
17 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPM 10000TL-HU vs Growatt MOD 10KTL3-HU
15 differences, the largest is european efficiency
Same type, similar size
Huawei
Huawei SUN2000-10KTL-M1 vs Huawei SUN2000-10KTL-M1 (High current version)
2 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.