Parameter MOD 9000TL3-XH MIN 9000TL-XH-US Difference
Warranty 5 yrs 10 yrs 5 yrs longer
Max DC voltage 1100 V 600 V 500 V apart
Max input current per tracker 16.0 A 13.5 A 2.5 A more headroom
Max AC power 9.90 kW 9.00 kW 0.90 kW apart
MPP trackers 2 4 2 trackers more
Weight 14.0 kg 20.5 kg 6.5 kg lighter
Weight per kW 1.6 kg/kW 2.3 kg/kW 0.7 kg/kW lighter
Max efficiency 98.6 % 98.3 % 0.3 pp more efficient
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 240 V 160 V apart
Max AC current 15.0 A 38.0 A 23.0 A apart
Start voltage 160 V 50 V 110 V earlier start
Ingress protection IP66 NEMA 4X (IP65) IP66 vs NEMA 4X (IP65)
MPPT voltage range 140-1000 V 50-550 V 140-1000 V vs 50-550 V
Battery voltage 600-950 V 360-550 V 600-950 V vs 360-550 V
Strings per tracker 1 2 1 string apart
Dimensions 387x425x178 mm 638x400x187 mm 387x425x178 mm vs 638x400x187 mm
02

Full specification

Parameter MOD 9000TL3-XH MIN 9000TL-XH-US Difference
AC output
Rated AC power 9.00 kW 9.00 kW Same
Max AC power 9.90 kW 9.00 kW 0.90 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 240 V 160 V apart
Max AC current 15.0 A 38.0 A 23.0 A apart
PV input
Max PV power 18.00 kW 18.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 1100 V 600 V 500 V apart
MPPT voltage range 140-1000 V 50-550 V 140-1000 V vs 50-550 V
Start voltage 160 V 50 V -110 V for MIN 9000TL-XH-US
MPP trackers 2 4 +2 trackers for MIN 9000TL-XH-US
Strings per tracker 1 2 1 string apart
Max input current per tracker 16.0 A 13.5 A +2.5 A for MOD 9000TL3-XH
Efficiency
European efficiency 98.1 % - Not published by Growatt
Max efficiency 98.6 % 98.3 % +0.3 pp for MOD 9000TL3-XH
CEC efficiency - 97.5 % Not published by Growatt
Battery
Battery input Yes Yes Same
Battery voltage 600-950 V 360-550 V 600-950 V vs 360-550 V
Max charge current - 30 A Not published by Growatt
Backup power - 11.4 kW Not published by Growatt
Physical
Weight 14.0 kg 20.5 kg -6.5 kg for MOD 9000TL3-XH
Weight per kW 1.6 kg/kW 2.3 kg/kW -0.7 kg/kW for MOD 9000TL3-XH
Dimensions 387x425x178 mm 638x400x187 mm 387x425x178 mm vs 638x400x187 mm
Ingress protection IP66 NEMA 4X (IP65) IP66 vs NEMA 4X (IP65)
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Growatt
Arc fault protection - Yes Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 10 yrs +5 yrs for MIN 9000TL-XH-US
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MOD 9000TL3-XH vs Growatt MOD 9000TL3-HU
8 differences, the largest is warranty
Same type, similar size
SolarEdge
Growatt MOD 9000TL3-XH vs SolarEdge SE9K
13 differences, the largest is warranty
Same type, similar size
Easun Power
Growatt MOD 9000TL3-XH vs Easun Power 8.5KW (8.5KVA/8.5KW, 48V)
13 differences, the largest is rated ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.