Skip to main content
MIN 9000TL-XH-US vs MOD 9000TL3-XH 8 of 25 identical Swap Change inverters

Growatt MIN 9000TL-XH-US vs Growatt MOD 9000TL3-XH

Growatt MIN 9000TL-XH-US
Growatt
MIN 9000TL-XH-US
9 kW Hybrid
VS
Growatt MOD 9000TL3-XH
Growatt
MOD 9000TL3-XH
9 kW 98.1 % euro Hybrid
The verdict

17 differences, and they point both ways

The largest is warranty: 5 yrs longer. 8 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
8 of 25 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 25 parameters
Parameter MIN 9000TL-XH-US MOD 9000TL3-XH Difference
Warranty 10 yrs 5 yrs 5 yrs longer
Max DC voltage 600 V 1100 V 500 V apart
Max input current per tracker 13.5 A 16.0 A 2.5 A more headroom
Max AC power 9.00 kW 9.90 kW 0.90 kW apart
MPP trackers 4 2 2 trackers more
Weight 20.5 kg 14.0 kg 6.5 kg lighter
Weight per kW 2.3 kg/kW 1.6 kg/kW 0.7 kg/kW lighter
Max efficiency 98.3 % 98.6 % 0.3 pp more efficient
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 240 V 400 V 160 V apart
Max AC current 38.0 A 15.0 A 23.0 A apart
Start voltage 50 V 160 V 110 V earlier start
Ingress protection NEMA 4X (IP65) IP66 NEMA 4X (IP65) vs IP66
MPPT voltage range 50-550 V 140-1000 V 50-550 V vs 140-1000 V
Battery voltage 360-550 V 600-950 V 360-550 V vs 600-950 V
Strings per tracker 2 1 1 string apart
Dimensions 638x400x187 mm 387x425x178 mm 638x400x187 mm vs 387x425x178 mm
02

Full specification

Parameter MIN 9000TL-XH-US MOD 9000TL3-XH Difference
AC output
Rated AC power 9.00 kW 9.00 kW Same
Max AC power 9.00 kW 9.90 kW 0.90 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 240 V 400 V 160 V apart
Max AC current 38.0 A 15.0 A 23.0 A apart
PV input
Max PV power 18.00 kW 18.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 50-550 V 140-1000 V 50-550 V vs 140-1000 V
Start voltage 50 V 160 V -110 V for MIN 9000TL-XH-US
MPP trackers 4 2 +2 trackers for MIN 9000TL-XH-US
Strings per tracker 2 1 1 string apart
Max input current per tracker 13.5 A 16.0 A +2.5 A for MOD 9000TL3-XH
Efficiency
European efficiency - 98.1 % Not published by Growatt
Max efficiency 98.3 % 98.6 % +0.3 pp for MOD 9000TL3-XH
CEC efficiency 97.5 % - Not published by Growatt
Battery
Battery input Yes Yes Same
Battery voltage 360-550 V 600-950 V 360-550 V vs 600-950 V
Max charge current 30 A - Not published by Growatt
Backup power 11.4 kW - Not published by Growatt
Physical
Weight 20.5 kg 14.0 kg -6.5 kg for MOD 9000TL3-XH
Weight per kW 2.3 kg/kW 1.6 kg/kW -0.7 kg/kW for MOD 9000TL3-XH
Dimensions 638x400x187 mm 387x425x178 mm 638x400x187 mm vs 387x425x178 mm
Ingress protection NEMA 4X (IP65) IP66 NEMA 4X (IP65) vs IP66
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Growatt
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 10 yrs 5 yrs +5 yrs for MIN 9000TL-XH-US
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MIN 9000TL-XH-US vs Growatt MOD 9000TL3-HU
16 differences, the largest is max dc voltage
Same type, similar size
SolarEdge
Growatt MIN 9000TL-XH-US vs SolarEdge SE9K
13 differences, the largest is warranty
Same type, similar size
Easun Power
Growatt MIN 9000TL-XH-US vs Easun Power 8.5KW (8.5KVA/8.5KW, 48V)
17 differences, the largest is rated ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.