Skip to main content
MOD 9000TL3-X vs SG9.0RS-L 9 of 22 identical Swap Change inverters

Growatt MOD 9000TL3-X vs Sungrow SG9.0RS-L

Growatt MOD 9000TL3-X
Growatt
MOD 9000TL3-X
9 kW 98.1 % euro Grid-tie
VS
Sungrow SG9.0RS-L
Sungrow
SG9.0RS-L
9 kW 97.4 % euro Grid-tie
The verdict

MOD 9000TL3-X leads on the differences that matter

The largest is european efficiency: 0.7 pp more efficient. 9 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
9 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 22 parameters
Parameter MOD 9000TL3-X SG9.0RS-L Difference
European efficiency 98.1 % 97.4 % 0.7 pp more efficient
Max DC voltage 1100 V 600 V 500 V apart
Max input current per tracker 13.0 A 16.0 A 3.0 A more headroom
Max efficiency 98.6 % 97.8 % 0.8 pp more efficient
Weight 14.0 kg 18.0 kg 4.0 kg lighter
Weight per kW 1.6 kg/kW 2.0 kg/kW 0.4 kg/kW lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Max AC current 15.0 A 41.0 A 26.0 A apart
Start voltage 160 V 50 V 110 V earlier start
MPP trackers 2 3 1 tracker more
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 40-560 V 140-1000 V vs 40-560 V
Dimensions 387x425x178 mm 365x525x170 mm 387x425x178 mm vs 365x525x170 mm
02

Full specification

Parameter MOD 9000TL3-X SG9.0RS-L Difference
AC output
Rated AC power 9.00 kW 9.00 kW Same
Max AC power 9.00 kW 9.00 kW Same
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V - Not published by Sungrow
Max AC current 15.0 A 41.0 A 26.0 A apart
PV input
Max PV power 13.50 kW 13.50 kW Same
DC/AC ratio 1.50 1.50 Same
Max DC voltage 1100 V 600 V 500 V apart
MPPT voltage range 140-1000 V 40-560 V 140-1000 V vs 40-560 V
Start voltage 160 V 50 V -110 V for SG9.0RS-L
MPP trackers 2 3 +1 trackers for SG9.0RS-L
Strings per tracker 1 1 Same
Max input current per tracker 13.0 A 16.0 A +3.0 A for SG9.0RS-L
Efficiency
European efficiency 98.1 % 97.4 % +0.7 pp for MOD 9000TL3-X
Max efficiency 98.6 % 97.8 % +0.8 pp for MOD 9000TL3-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 14.0 kg 18.0 kg -4.0 kg for MOD 9000TL3-X
Weight per kW 1.6 kg/kW 2.0 kg/kW -0.4 kg/kW for MOD 9000TL3-X
Dimensions 387x425x178 mm 365x525x170 mm 387x425x178 mm vs 365x525x170 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Sungrow
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Sungrow
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
Growatt MOD 9000TL3-X vs Ginlong Solis S6-GR3P-9K02-NV-ND
6 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Growatt MOD 9000TL3-X vs Solis-3P9K-4G
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MOD 9000TL3-X vs Growatt MIN 9000TL-X
12 differences, the largest is european efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.