Skip to main content
MOD 9000TL3-X vs Solis-3P9K-4G 7 of 20 identical Swap Change inverters

Growatt MOD 9000TL3-X vs Solis-3P9K-4G

Growatt MOD 9000TL3-X
Growatt
MOD 9000TL3-X
9 kW 98.1 % euro Grid-tie
VS
Ginlong Solis
Solis-3P9K-4G
9 kW 97.8 % euro Grid-tie
The verdict

MOD 9000TL3-X leads on the differences that matter

The largest is max dc voltage: 100 V apart. 7 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
7 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 20 parameters
Parameter MOD 9000TL3-X Solis-3P9K-4G Difference
Max DC voltage 1100 V 1000 V 100 V apart
Max AC power 9.00 kW 9.90 kW 0.90 kW apart
Max PV power 13.50 kW 10.80 kW 2.70 kW apart
DC/AC ratio 1.50 1.20 0.30 more oversizing headroom
Weight 14.0 kg 18.0 kg 4.0 kg lighter
European efficiency 98.1 % 97.8 % 0.3 pp more efficient
Max efficiency 98.6 % 98.3 % 0.3 pp more efficient
Weight per kW 1.6 kg/kW 2.0 kg/kW 0.4 kg/kW lighter
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 160-850 V 140-1000 V vs 160-850 V
Start voltage 160 V 180 V 20 V earlier start
Max AC current 15.0 A 14.3 A 0.7 A apart
Dimensions 387x425x178 mm 563x310x219 mm 387x425x178 mm vs 563x310x219 mm
02

Full specification

Parameter MOD 9000TL3-X Solis-3P9K-4G Difference
AC output
Rated AC power 9.00 kW 9.00 kW Same
Max AC power 9.00 kW 9.90 kW 0.90 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 15.0 A 14.3 A 0.7 A apart
PV input
Max PV power 13.50 kW 10.80 kW 2.70 kW apart
DC/AC ratio 1.50 1.20 +0.30 for MOD 9000TL3-X
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 140-1000 V 160-850 V 140-1000 V vs 160-850 V
Start voltage 160 V 180 V -20 V for MOD 9000TL3-X
MPP trackers 2 2 Same
Strings per tracker 1 - Not published by Ginlong Solis
Max input current per tracker 13.0 A - Not published by Ginlong Solis
Efficiency
European efficiency 98.1 % 97.8 % +0.3 pp for MOD 9000TL3-X
Max efficiency 98.6 % 98.3 % +0.3 pp for MOD 9000TL3-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 14.0 kg 18.0 kg -4.0 kg for MOD 9000TL3-X
Weight per kW 1.6 kg/kW 2.0 kg/kW -0.4 kg/kW for MOD 9000TL3-X
Dimensions 387x425x178 mm 563x310x219 mm 387x425x178 mm vs 563x310x219 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural - Not published by Ginlong Solis
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Ginlong Solis
Arc fault protection - Yes Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
Growatt MOD 9000TL3-X vs Ginlong Solis S6-GR3P-9K02-NV-ND
6 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MOD 9000TL3-X vs Growatt MIN 9000TL-X
12 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Growatt MOD 9000TL3-X vs SolarEdge SE9K-RWZZZBEN4 (per inverter; bundle is 2×SE9K, marketed as SE18K-BUNDLE*)
9 differences, the largest is european efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.