Skip to main content
MOD 9000TL3-X vs SE16K (Delta grid version; part no. SExxK-xxxxxbxx4) 4 of 19 identical Swap Change inverters

Growatt MOD 9000TL3-X vs SolarEdge SE16K (Delta grid version; part no. SExxK-xxxxxbxx4)

Growatt MOD 9000TL3-X
Growatt
MOD 9000TL3-X
9 kW 98.1 % euro Grid-tie
VS
SolarEdge SE16K (Delta grid version; part no. SExxK-xxxxxbxx4)
SolarEdge
SE16K (Delta grid version; part no. SExxK-xxxxxbxx4)
9.2 kW 97.7 % euro Grid-tie
The verdict

MOD 9000TL3-X leads on the differences that matter

The largest is rated ac power: 0.20 kW apart. 4 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
4 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 19 parameters
Parameter MOD 9000TL3-X SE16K (Delta grid version; part no. SExxK-xxxxxbxx4) Difference
Rated AC power 9.00 kW 9.20 kW 0.20 kW apart
Max DC voltage 1100 V 600 V 500 V apart
European efficiency 98.1 % 97.7 % 0.4 pp more efficient
Max efficiency 98.6 % 98.0 % 0.6 pp more efficient
Max PV power 13.50 kW 12.42 kW 1.08 kW apart
Weight 14.0 kg 30.7 kg 16.7 kg lighter
Weight per kW 1.6 kg/kW 3.3 kg/kW 1.8 kg/kW lighter
Max AC power 9.00 kW 9.20 kW 0.20 kW apart
DC/AC ratio 1.50 1.35 0.15 more oversizing headroom
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 15.0 A 25.5 A 10.5 A apart
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 370-600 V 140-1000 V vs 370-600 V
Dimensions 387x425x178 mm 540x315x260 mm 387x425x178 mm vs 540x315x260 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MOD 9000TL3-X SE16K (Delta grid version; part no. SExxK-xxxxxbxx4) Difference
AC output
Rated AC power 9.00 kW 9.20 kW 0.20 kW apart
Max AC power 9.00 kW 9.20 kW 0.20 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 15.0 A 25.5 A 10.5 A apart
PV input
Max PV power 13.50 kW 12.42 kW 1.08 kW apart
DC/AC ratio 1.50 1.35 +0.15 for MOD 9000TL3-X
Max DC voltage 1100 V 600 V 500 V apart
MPPT voltage range 140-1000 V 370-600 V 140-1000 V vs 370-600 V
Start voltage 160 V - Not published by SolarEdge
MPP trackers 2 - Not published by SolarEdge
Strings per tracker 1 - Not published by SolarEdge
Max input current per tracker 13.0 A - Not published by SolarEdge
Efficiency
European efficiency 98.1 % 97.7 % +0.4 pp for MOD 9000TL3-X
Max efficiency 98.6 % 98.0 % +0.6 pp for MOD 9000TL3-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 14.0 kg 30.7 kg -16.7 kg for MOD 9000TL3-X
Weight per kW 1.6 kg/kW 3.3 kg/kW -1.8 kg/kW for MOD 9000TL3-X
Dimensions 387x425x178 mm 540x315x260 mm 387x425x178 mm vs 540x315x260 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural forced-air natural vs forced-air
Noise - 50 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection - Yes Not published by Growatt
Integrated DC switch Yes - Not published by SolarEdge
Warranty
Warranty 5 yrs - Not published by SolarEdge
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
Growatt MOD 9000TL3-X vs Ginlong Solis S6-GR3P-9K02-NV-ND
6 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Growatt MOD 9000TL3-X vs Solis-3P9K-4G
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MOD 9000TL3-X vs Growatt MIN 9000TL-X
12 differences, the largest is european efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.