Growatt MOD 8000TL3-HU vs Growatt SPM 8000TL-HU
VS
The verdict
MOD 8000TL3-HU leads on the differences that matter
The largest is european efficiency: 1.6 pp more efficient. 11 of 28 comparable parameters are identical, with 4 more left out because at least one datasheet does not publish them.
See all 17 differencesHow alike are they
11
of 28 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
17 of 28 parameters
What actually differs
Parameter
MOD 8000TL3-HU
SPM 8000TL-HU
Difference
European efficiency
98.1 %
96.5 %
1.6 pp more efficient
Max DC voltage
1000 V
600 V
400 V apart
Max efficiency
98.6 %
97.5 %
1.1 pp more efficient
Max AC power
8.80 kW
8.00 kW
0.80 kW apart
Max charge current
25 A
200 A
175 A faster charging
Weight
19.0 kg
48.8 kg
29.8 kg lighter
Weight per kW
2.4 kg/kW
6.1 kg/kW
3.7 kg/kW lighter
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
13.3 A
40.0 A
26.7 A apart
Start voltage
180 V
120 V
60 V earlier start
MPP trackers
2
3
1 tracker more
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
140-1000 V
150-500 V
140-1000 V vs 150-500 V
Battery voltage
600-980 V
40-60 V
600-980 V vs 40-60 V
Dimensions
468x408x202 mm
883x440x256 mm
468x408x202 mm vs 883x440x256 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MOD 8000TL3-HU
SPM 8000TL-HU
Difference
AC output
Rated AC power
8.00 kW
8.00 kW
Same
Max AC power
8.80 kW
8.00 kW
0.80 kW apart
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
13.3 A
40.0 A
26.7 A apart
PV input
Max PV power
16.00 kW
16.00 kW
Same
DC/AC ratio
2.00
2.00
Same
Max DC voltage
1000 V
600 V
400 V apart
MPPT voltage range
140-1000 V
150-500 V
140-1000 V vs 150-500 V
Start voltage
180 V
120 V
-60 V for SPM 8000TL-HU
MPP trackers
2
3
+1 trackers for SPM 8000TL-HU
Strings per tracker
1
1
Same
Max input current per tracker
20.0 A
-
Not published by Growatt
Efficiency
European efficiency
98.1 %
96.5 %
+1.6 pp for MOD 8000TL3-HU
Max efficiency
98.6 %
97.5 %
+1.1 pp for MOD 8000TL3-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
40-60 V
600-980 V vs 40-60 V
Max charge current
25 A
200 A
+175 A for SPM 8000TL-HU
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
19.0 kg
48.8 kg
-29.8 kg for MOD 8000TL3-HU
Weight per kW
2.4 kg/kW
6.1 kg/kW
-3.7 kg/kW for MOD 8000TL3-HU
Dimensions
468x408x202 mm
883x440x256 mm
468x408x202 mm vs 883x440x256 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
forced-air
natural vs forced-air
Noise
29 dB
30 dB
Effectively the same
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
10 yrs
10 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MOD 8000TL3-HU vs SolarEdge SE8000H
10 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 8000TL3-HU vs Growatt MOD 8000TL3-XH
8 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 8000TL3-HU vs Huawei SUN5000-8K-MAP0
10 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.