Skip to main content
MOD 8000TL3-HU vs MIN 8200TL-XH-US 9 of 27 identical Swap Change inverters

Growatt MOD 8000TL3-HU vs Growatt MIN 8200TL-XH-US

Growatt MOD 8000TL3-HU
Growatt
MOD 8000TL3-HU
8 kW 98.1 % euro Hybrid
VS
Growatt MIN 8200TL-XH-US
Growatt
MIN 8200TL-XH-US
8.2 kW Hybrid
The verdict

18 differences, and they point both ways

The largest is rated ac power: 0.20 kW apart. 9 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.

See all 18 differences
How alike are they
9 of 27 comparable
parameters are identical
identical differs not published
01

What actually differs

18 of 27 parameters
Parameter MOD 8000TL3-HU MIN 8200TL-XH-US Difference
Rated AC power 8.00 kW 8.20 kW 0.20 kW apart
Max DC voltage 1000 V 600 V 400 V apart
Max input current per tracker 20.0 A 13.5 A 6.5 A more headroom
Max AC power 8.80 kW 8.20 kW 0.60 kW apart
MPP trackers 2 4 2 trackers more
Max charge current 25 A 30 A 5 A faster charging
Max PV power 16.00 kW 16.40 kW 0.40 kW apart
Weight 19.0 kg 20.5 kg 1.5 kg lighter
Max efficiency 98.6 % 98.3 % 0.3 pp more efficient
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 240 V 160 V apart
Max AC current 13.3 A 35.0 A 21.7 A apart
Start voltage 180 V 50 V 130 V earlier start
Ingress protection IP66 NEMA 4X (IP65) IP66 vs NEMA 4X (IP65)
MPPT voltage range 140-1000 V 50-550 V 140-1000 V vs 50-550 V
Battery voltage 600-980 V 360-550 V 600-980 V vs 360-550 V
Strings per tracker 1 2 1 string apart
Dimensions 468x408x202 mm 638x400x187 mm 468x408x202 mm vs 638x400x187 mm
02

Full specification

Parameter MOD 8000TL3-HU MIN 8200TL-XH-US Difference
AC output
Rated AC power 8.00 kW 8.20 kW 0.20 kW apart
Max AC power 8.80 kW 8.20 kW 0.60 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 240 V 160 V apart
Max AC current 13.3 A 35.0 A 21.7 A apart
PV input
Max PV power 16.00 kW 16.40 kW 0.40 kW apart
DC/AC ratio 2.00 2.00 Same
Max DC voltage 1000 V 600 V 400 V apart
MPPT voltage range 140-1000 V 50-550 V 140-1000 V vs 50-550 V
Start voltage 180 V 50 V -130 V for MIN 8200TL-XH-US
MPP trackers 2 4 +2 trackers for MIN 8200TL-XH-US
Strings per tracker 1 2 1 string apart
Max input current per tracker 20.0 A 13.5 A +6.5 A for MOD 8000TL3-HU
Efficiency
European efficiency 98.1 % - Not published by Growatt
Max efficiency 98.6 % 98.3 % +0.3 pp for MOD 8000TL3-HU
CEC efficiency - 97.5 % Not published by Growatt
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 360-550 V 600-980 V vs 360-550 V
Max charge current 25 A 30 A +5 A for MIN 8200TL-XH-US
Backup power - 11.4 kW Not published by Growatt
Physical
Weight 19.0 kg 20.5 kg -1.5 kg for MOD 8000TL3-HU
Weight per kW 2.4 kg/kW 2.5 kg/kW Effectively the same
Dimensions 468x408x202 mm 638x400x187 mm 468x408x202 mm vs 638x400x187 mm
Ingress protection IP66 NEMA 4X (IP65) IP66 vs NEMA 4X (IP65)
Cooling natural natural Same
Noise 29 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty 10 yrs 10 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 8000TL3-HU vs SolarEdge SE8000H
10 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 8000TL3-HU vs Growatt MOD 8000TL3-XH
8 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 8000TL3-HU vs Huawei SUN5000-8K-MAP0
10 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.