Skip to main content
MOD 5000TL3-HU vs RHI-5K-48ES-5G 8 of 26 identical Swap Change inverters

Growatt MOD 5000TL3-HU vs Ginlong Solis RHI-5K-48ES-5G

Growatt MOD 5000TL3-HU
Growatt
MOD 5000TL3-HU
5 kW 97.8 % euro Hybrid
VS
Ginlong Solis RHI-5K-48ES-5G
Ginlong Solis
RHI-5K-48ES-5G
5 kW 96.8 % euro Hybrid
The verdict

MOD 5000TL3-HU leads on the differences that matter

The largest is european efficiency: 1.0 pp more efficient. 8 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 18 differences
How alike are they
8 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

18 of 26 parameters
Parameter MOD 5000TL3-HU RHI-5K-48ES-5G Difference
European efficiency 97.8 % 96.8 % 1.0 pp more efficient
Max DC voltage 1000 V 600 V 400 V apart
Max input current per tracker 20.0 A 11.0 A 9.0 A more headroom
Max efficiency 98.3 % 97.5 % 0.8 pp more efficient
Max AC power 5.50 kW 5.00 kW 0.50 kW apart
Max PV power 10.00 kW 8.00 kW 2.00 kW apart
DC/AC ratio 2.00 1.60 0.40 more oversizing headroom
Max charge current 25 A 100 A 75 A faster charging
Weight 19.0 kg 17.0 kg 2.0 kg lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 8.3 A 23.9 A 15.6 A apart
Start voltage 180 V 120 V 60 V earlier start
Weight per kW 3.8 kg/kW 3.4 kg/kW 0.4 kg/kW lighter
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 90-520 V 140-1000 V vs 90-520 V
Battery voltage 600-980 V 42-58 V 600-980 V vs 42-58 V
Dimensions 468x408x202 mm 505x333x249 mm 468x408x202 mm vs 505x333x249 mm
02

Full specification

Parameter MOD 5000TL3-HU RHI-5K-48ES-5G Difference
AC output
Rated AC power 5.00 kW 5.00 kW Same
Max AC power 5.50 kW 5.00 kW 0.50 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 8.3 A 23.9 A 15.6 A apart
PV input
Max PV power 10.00 kW 8.00 kW 2.00 kW apart
DC/AC ratio 2.00 1.60 +0.40 for MOD 5000TL3-HU
Max DC voltage 1000 V 600 V 400 V apart
MPPT voltage range 140-1000 V 90-520 V 140-1000 V vs 90-520 V
Start voltage 180 V 120 V -60 V for RHI-5K-48ES-5G
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 20.0 A 11.0 A +9.0 A for MOD 5000TL3-HU
Efficiency
European efficiency 97.8 % 96.8 % +1.0 pp for MOD 5000TL3-HU
Max efficiency 98.3 % 97.5 % +0.8 pp for MOD 5000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 42-58 V 600-980 V vs 42-58 V
Max charge current 25 A 100 A +75 A for RHI-5K-48ES-5G
Backup power - 5.0 kW Not published by Growatt
Physical
Weight 19.0 kg 17.0 kg -2.0 kg for RHI-5K-48ES-5G
Weight per kW 3.8 kg/kW 3.4 kg/kW -0.4 kg/kW for RHI-5K-48ES-5G
Dimensions 468x408x202 mm 505x333x249 mm 468x408x202 mm vs 505x333x249 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise 29 dB - Not published by Ginlong Solis
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes Yes Same
Integrated DC switch Yes - Not published by Ginlong Solis
Warranty
Warranty 10 yrs - Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 5000TL3-HU vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
13 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Growatt MOD 5000TL3-HU vs SolarEdge SE5000H
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 5000TL3-HU vs Huawei SUN2000L-5KTL
15 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.