Skip to main content
RHI-5K-48ES-5G vs MOD 5000TL3-HU 8 of 26 identical Swap Change inverters

Ginlong Solis RHI-5K-48ES-5G vs Growatt MOD 5000TL3-HU

Ginlong Solis RHI-5K-48ES-5G
Ginlong Solis
RHI-5K-48ES-5G
5 kW 96.8 % euro Hybrid
VS
Growatt MOD 5000TL3-HU
Growatt
MOD 5000TL3-HU
5 kW 97.8 % euro Hybrid
The verdict

MOD 5000TL3-HU leads on the differences that matter

The largest is european efficiency: 1.0 pp more efficient. 8 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 18 differences
How alike are they
8 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

18 of 26 parameters
Parameter RHI-5K-48ES-5G MOD 5000TL3-HU Difference
European efficiency 96.8 % 97.8 % 1.0 pp more efficient
Max DC voltage 600 V 1000 V 400 V apart
Max input current per tracker 11.0 A 20.0 A 9.0 A more headroom
Max efficiency 97.5 % 98.3 % 0.8 pp more efficient
Max AC power 5.00 kW 5.50 kW 0.50 kW apart
Max PV power 8.00 kW 10.00 kW 2.00 kW apart
DC/AC ratio 1.60 2.00 0.40 more oversizing headroom
Max charge current 100 A 25 A 75 A faster charging
Weight 17.0 kg 19.0 kg 2.0 kg lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 23.9 A 8.3 A 15.6 A apart
Start voltage 120 V 180 V 60 V earlier start
Weight per kW 3.4 kg/kW 3.8 kg/kW 0.4 kg/kW lighter
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 90-520 V 140-1000 V 90-520 V vs 140-1000 V
Battery voltage 42-58 V 600-980 V 42-58 V vs 600-980 V
Dimensions 505x333x249 mm 468x408x202 mm 505x333x249 mm vs 468x408x202 mm
02

Full specification

Parameter RHI-5K-48ES-5G MOD 5000TL3-HU Difference
AC output
Rated AC power 5.00 kW 5.00 kW Same
Max AC power 5.00 kW 5.50 kW 0.50 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 23.9 A 8.3 A 15.6 A apart
PV input
Max PV power 8.00 kW 10.00 kW 2.00 kW apart
DC/AC ratio 1.60 2.00 +0.40 for MOD 5000TL3-HU
Max DC voltage 600 V 1000 V 400 V apart
MPPT voltage range 90-520 V 140-1000 V 90-520 V vs 140-1000 V
Start voltage 120 V 180 V -60 V for RHI-5K-48ES-5G
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 11.0 A 20.0 A +9.0 A for MOD 5000TL3-HU
Efficiency
European efficiency 96.8 % 97.8 % +1.0 pp for MOD 5000TL3-HU
Max efficiency 97.5 % 98.3 % +0.8 pp for MOD 5000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 42-58 V 600-980 V 42-58 V vs 600-980 V
Max charge current 100 A 25 A +75 A for RHI-5K-48ES-5G
Backup power 5.0 kW - Not published by Growatt
Physical
Weight 17.0 kg 19.0 kg -2.0 kg for RHI-5K-48ES-5G
Weight per kW 3.4 kg/kW 3.8 kg/kW -0.4 kg/kW for RHI-5K-48ES-5G
Dimensions 505x333x249 mm 468x408x202 mm 505x333x249 mm vs 468x408x202 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - 29 dB Not published by Ginlong Solis
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes Yes Same
Integrated DC switch - Yes Not published by Ginlong Solis
Warranty
Warranty - 10 yrs Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Ginlong Solis RHI-5K-48ES-5G vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
7 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Ginlong Solis RHI-5K-48ES-5G vs SolarEdge SE5000H
9 differences, the largest is european efficiency
Same type, similar size
Huawei
Ginlong Solis RHI-5K-48ES-5G vs Huawei SUN2000L-5KTL
10 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 5000TL3-HU vs Huawei SUN2000-5KTL-L1
16 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.