Skip to main content
MOD 15KTL3-HU vs WIT 15K-XHU 11 of 27 identical Swap Change inverters

Growatt MOD 15KTL3-HU vs Growatt WIT 15K-XHU

Growatt MOD 15KTL3-HU
Growatt
MOD 15KTL3-HU
15 kW 98.1 % euro Hybrid
VS
Growatt WIT 15K-XHU
Growatt
WIT 15K-XHU
15 kW 97.2 % euro Hybrid
The verdict

MOD 15KTL3-HU leads on the differences that matter

The largest is european efficiency: 0.9 pp more efficient. 11 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
11 of 27 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 27 parameters
Parameter MOD 15KTL3-HU WIT 15K-XHU Difference
European efficiency 98.1 % 97.2 % 0.9 pp more efficient
Max input current per tracker 20.0 A 40.0 A 20.0 A more headroom
Max AC power 15.00 kW 16.50 kW 1.50 kW apart
Max charge current 25 A 55 A 30 A faster charging
Weight 20.0 kg 45.0 kg 25.0 kg lighter
Weight per kW 1.3 kg/kW 3.0 kg/kW 1.7 kg/kW lighter
Noise 29 dB 55 dB 26 dB quieter
Max efficiency 98.6 % 98.1 % 0.5 pp more efficient
Max AC current 25.0 A 50.0 A 25.0 A apart
MPP trackers 3 2 1 tracker more
MPPT voltage range 140-1000 V 150-850 V 140-1000 V vs 150-850 V
Start voltage 160 V 180 V 20 V earlier start
Battery voltage 600-980V 120-800V 600-980V vs 120-800V
Strings per tracker 1 2 1 string apart
Dimensions 480x468x202 mm 456x684x240 mm 480x468x202 mm vs 456x684x240 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MOD 15KTL3-HU WIT 15K-XHU Difference
AC output
Rated AC power 15.00 kW 15.00 kW Same
Max AC power 15.00 kW 16.50 kW 1.50 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 25.0 A 50.0 A 25.0 A apart
PV input
Max PV power 30.00 kW 30.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 1000 V 1000 V Same
MPPT voltage range 140-1000 V 150-850 V 140-1000 V vs 150-850 V
Start voltage 160 V 180 V -20 V for MOD 15KTL3-HU
MPP trackers 3 2 +1 trackers for MOD 15KTL3-HU
Strings per tracker 1 2 1 string apart
Max input current per tracker 20.0 A 40.0 A +20.0 A for WIT 15K-XHU
Efficiency
European efficiency 98.1 % 97.2 % +0.9 pp for MOD 15KTL3-HU
Max efficiency 98.6 % 98.1 % +0.5 pp for MOD 15KTL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980V 120-800V 600-980V vs 120-800V
Max charge current 25 A 55 A +30 A for WIT 15K-XHU
Backup power - - Neither datasheet publishes this
Physical
Weight 20.0 kg 45.0 kg -25.0 kg for MOD 15KTL3-HU
Weight per kW 1.3 kg/kW 3.0 kg/kW -1.7 kg/kW for MOD 15KTL3-HU
Dimensions 480x468x202 mm 456x684x240 mm 480x468x202 mm vs 456x684x240 mm
Ingress protection IP66 IP66 Same
Cooling natural forced-air natural vs forced-air
Noise 29 dB 55 dB -26 dB for MOD 15KTL3-HU
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 10 yrs - Not published by Growatt
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MOD 15KTL3-HU vs Growatt MID 15KTL3-XH
12 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 15KTL3-HU vs Huawei SUN2000-15K-MB0
15 differences, the largest is max dc voltage
Same type, similar size
Sofar Solar
Growatt MOD 15KTL3-HU vs Sofar Solar HYD 15KTL-3PH
14 differences, the largest is european efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.