Growatt MOD 15KTL3-HU vs Huawei SUN2000-15K-MB0
VS
The verdict
MOD 15KTL3-HU leads on the differences that matter
The largest is max dc voltage: 100 V apart. 12 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
12
of 27 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 27 parameters
What actually differs
Parameter
MOD 15KTL3-HU
SUN2000-15K-MB0
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
20.0 A
30.0 A
10.0 A more headroom
Max AC power
15.00 kW
16.50 kW
1.50 kW apart
Max PV power
30.00 kW
22.50 kW
7.50 kW apart
DC/AC ratio
2.00
1.50
0.50 more oversizing headroom
Start voltage
160 V
200 V
40 V earlier start
MPP trackers
3
2
1 tracker more
Weight
20.0 kg
21.0 kg
1.0 kg lighter
Max efficiency
98.6 %
98.4 %
0.2 pp more efficient
Max charge current
25 A
26 A
1 A faster charging
MPPT voltage range
140-1000 V
200-1000 V
140-1000 V vs 200-1000 V
Battery voltage
600-980V
600 V ~ 980 V
600-980V vs 600 V ~ 980 V
Strings per tracker
1
2
1 string apart
Dimensions
480x468x202 mm
460x546x242 mm
480x468x202 mm vs 460x546x242 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MOD 15KTL3-HU
SUN2000-15K-MB0
Difference
AC output
Rated AC power
15.00 kW
15.00 kW
Same
Max AC power
15.00 kW
16.50 kW
1.50 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
25.0 A
25.2 A
Effectively the same
PV input
Max PV power
30.00 kW
22.50 kW
7.50 kW apart
DC/AC ratio
2.00
1.50
+0.50 for MOD 15KTL3-HU
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
140-1000 V
200-1000 V
140-1000 V vs 200-1000 V
Start voltage
160 V
200 V
-40 V for MOD 15KTL3-HU
MPP trackers
3
2
+1 trackers for MOD 15KTL3-HU
Strings per tracker
1
2
1 string apart
Max input current per tracker
20.0 A
30.0 A
+10.0 A for SUN2000-15K-MB0
Efficiency
European efficiency
98.1 %
98.0 %
Effectively the same
Max efficiency
98.6 %
98.4 %
+0.2 pp for MOD 15KTL3-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980V
600 V ~ 980 V
600-980V vs 600 V ~ 980 V
Max charge current
25 A
26 A
+1 A for SUN2000-15K-MB0
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
20.0 kg
21.0 kg
-1.0 kg for MOD 15KTL3-HU
Weight per kW
1.3 kg/kW
1.4 kg/kW
Effectively the same
Dimensions
480x468x202 mm
460x546x242 mm
480x468x202 mm vs 460x546x242 mm
Ingress protection
IP66
IP66
Same
Cooling
natural
forced-air
natural vs forced-air
Noise
29 dB
-
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
10 yrs
-
Not published by Huawei
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MOD 15KTL3-HU vs Growatt MID 15KTL3-XH
12 differences, the largest is warranty
Same type, similar size
Sofar Solar
Growatt MOD 15KTL3-HU vs Sofar Solar HYD 15KTL-3PH
14 differences, the largest is european efficiency
Same type, similar size
Sungrow
Growatt MOD 15KTL3-HU vs Sungrow SH15T
14 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.