Skip to main content
MOD 15KTL3-HU vs SUN-15K-SG01HP3-EU-AM2 9 of 28 identical Swap Change inverters

Growatt MOD 15KTL3-HU vs Deye SUN-15K-SG01HP3-EU-AM2

Growatt MOD 15KTL3-HU
Growatt
MOD 15KTL3-HU
15 kW 98.1 % euro Hybrid
VS
Deye SUN-15K-SG01HP3-EU-AM2
Deye
SUN-15K-SG01HP3-EU-AM2
15 kW 97.0 % euro Hybrid
The verdict

MOD 15KTL3-HU leads on the differences that matter

The largest is european efficiency: 1.1 pp more efficient. 9 of 28 comparable parameters are identical, with 4 more left out because at least one datasheet does not publish them.

See all 19 differences
How alike are they
9 of 28 comparable
parameters are identical
identical differs not published
01

What actually differs

19 of 28 parameters
Parameter MOD 15KTL3-HU SUN-15K-SG01HP3-EU-AM2 Difference
European efficiency 98.1 % 97.0 % 1.1 pp more efficient
Warranty 10 yrs 5 yrs 5 yrs longer
Max input current per tracker 20.0 A 26.0 A 6.0 A more headroom
Max efficiency 98.6 % 97.6 % 1.0 pp more efficient
Max AC power 15.00 kW 16.50 kW 1.50 kW apart
Max PV power 30.00 kW 19.50 kW 10.50 kW apart
DC/AC ratio 2.00 1.30 0.70 more oversizing headroom
Max charge current 25 A 50 A 25 A faster charging
Weight 20.0 kg 30.5 kg 10.5 kg lighter
Noise 29 dB 55 dB 26 dB quieter
Weight per kW 1.3 kg/kW 2.0 kg/kW 0.7 kg/kW lighter
Max AC current 25.0 A 27.3 A 2.3 A apart
MPP trackers 3 2 1 tracker more
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 150-850 V 140-1000 V vs 150-850 V
Start voltage 160 V 180 V 20 V earlier start
Battery voltage 600-980V 160-700 600-980V vs 160-700
Strings per tracker 1 2 1 string apart
Dimensions 480x468x202 mm 638x408x237 mm 480x468x202 mm vs 638x408x237 mm
02

Full specification

Parameter MOD 15KTL3-HU SUN-15K-SG01HP3-EU-AM2 Difference
AC output
Rated AC power 15.00 kW 15.00 kW Same
Max AC power 15.00 kW 16.50 kW 1.50 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 25.0 A 27.3 A 2.3 A apart
PV input
Max PV power 30.00 kW 19.50 kW 10.50 kW apart
DC/AC ratio 2.00 1.30 +0.70 for MOD 15KTL3-HU
Max DC voltage 1000 V 1000 V Same
MPPT voltage range 140-1000 V 150-850 V 140-1000 V vs 150-850 V
Start voltage 160 V 180 V -20 V for MOD 15KTL3-HU
MPP trackers 3 2 +1 trackers for MOD 15KTL3-HU
Strings per tracker 1 2 1 string apart
Max input current per tracker 20.0 A 26.0 A +6.0 A for SUN-15K-SG01HP3-EU-AM2
Efficiency
European efficiency 98.1 % 97.0 % +1.1 pp for MOD 15KTL3-HU
Max efficiency 98.6 % 97.6 % +1.0 pp for MOD 15KTL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980V 160-700 600-980V vs 160-700
Max charge current 25 A 50 A +25 A for SUN-15K-SG01HP3-EU-AM2
Backup power - - Neither datasheet publishes this
Physical
Weight 20.0 kg 30.5 kg -10.5 kg for MOD 15KTL3-HU
Weight per kW 1.3 kg/kW 2.0 kg/kW -0.7 kg/kW for MOD 15KTL3-HU
Dimensions 480x468x202 mm 638x408x237 mm 480x468x202 mm vs 638x408x237 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise 29 dB 55 dB -26 dB for MOD 15KTL3-HU
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Growatt
Arc fault protection Yes - Not published by Deye
Integrated DC switch Yes Yes Same
Warranty
Warranty 10 yrs 5 yrs +5 yrs for MOD 15KTL3-HU
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MOD 15KTL3-HU vs Growatt MID 15KTL3-XH
12 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 15KTL3-HU vs Huawei SUN2000-15K-MB0
15 differences, the largest is max dc voltage
Same type, similar size
Sofar Solar
Growatt MOD 15KTL3-HU vs Sofar Solar HYD 15KTL-3PH
14 differences, the largest is european efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.