Growatt MOD 11KTL3-X vs Deye SUN-10.5K-G
VS
The verdict
MOD 11KTL3-X leads on the differences that matter
The largest is rated ac power: 0.50 kW apart. 6 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 18 differencesHow alike are they
6
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
18 of 24 parameters
What actually differs
Parameter
MOD 11KTL3-X
SUN-10.5K-G
Difference
Rated AC power
11.00 kW
10.50 kW
0.50 kW apart
European efficiency
98.1 %
97.5 %
0.6 pp more efficient
Max DC voltage
1100 V
550 V
550 V apart
Max efficiency
98.6 %
97.7 %
0.9 pp more efficient
Max AC power
11.00 kW
11.60 kW
0.60 kW apart
Max PV power
16.50 kW
13.70 kW
2.80 kW apart
DC/AC ratio
1.50
1.30
0.20 more oversizing headroom
Weight
14.0 kg
15.7 kg
1.7 kg lighter
Max input current per tracker
26.0 A
25.0 A
1.0 A more headroom
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
18.3 A
50.2 A
31.9 A apart
Start voltage
160 V
80 V
80 V earlier start
Max operating temperature
60 °C
65 °C
5 °C more heat tolerant
Ingress protection
IP66
IP65
IP66 vs IP65
Weight per kW
1.3 kg/kW
1.5 kg/kW
0.2 kg/kW lighter
MPPT voltage range
140-1000 V
70-550 V
140-1000 V vs 70-550 V
Dimensions
387x425x178 mm
410x330x198 mm
387x425x178 mm vs 410x330x198 mm
02
Full specification
Parameter
MOD 11KTL3-X
SUN-10.5K-G
Difference
AC output
Rated AC power
11.00 kW
10.50 kW
0.50 kW apart
Max AC power
11.00 kW
11.60 kW
0.60 kW apart
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
18.3 A
50.2 A
31.9 A apart
PV input
Max PV power
16.50 kW
13.70 kW
2.80 kW apart
DC/AC ratio
1.50
1.30
+0.20 for MOD 11KTL3-X
Max DC voltage
1100 V
550 V
550 V apart
MPPT voltage range
140-1000 V
70-550 V
140-1000 V vs 70-550 V
Start voltage
160 V
80 V
-80 V for SUN-10.5K-G
MPP trackers
2
2
Same
Strings per tracker
2
2
Same
Max input current per tracker
26.0 A
25.0 A
+1.0 A for MOD 11KTL3-X
Efficiency
European efficiency
98.1 %
97.5 %
+0.6 pp for MOD 11KTL3-X
Max efficiency
98.6 %
97.7 %
+0.9 pp for MOD 11KTL3-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
14.0 kg
15.7 kg
-1.7 kg for MOD 11KTL3-X
Weight per kW
1.3 kg/kW
1.5 kg/kW
-0.2 kg/kW for MOD 11KTL3-X
Dimensions
387x425x178 mm
410x330x198 mm
387x425x178 mm vs 410x330x198 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
-
25 dB
Not published by Growatt
Max operating temperature
60 °C
65 °C
+5 °C for SUN-10.5K-G
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Deye
03
Open all inverters
More useful comparisons
Same type, similar size
Fronius International
Growatt MOD 11KTL3-X vs Fronius Primo 11.4-1
16 differences, the largest is rated ac power
Same type, similar size
Sofar Solar
Growatt MOD 11KTL3-X vs SOFAR 10.5KTLM-G3
17 differences, the largest is rated ac power
Same type, similar size
Fronius International
Growatt MOD 11KTL3-X vs Fronius Symo Advanced 12.0-3 208-240
13 differences, the largest is rated ac power
Same type, similar size
Growatt
Deye SUN-10.5K-G vs Growatt MOD 10KTL3-X2(Pro)
18 differences, the largest is rated ac power
Same type, similar size
Growatt
Deye SUN-10.5K-G vs Growatt MOD 10KTL3-X
17 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.