Deye SUN-10.5K-G vs Growatt MOD 10KTL3-X2(Pro)
VS
The verdict
MOD 10KTL3-X2(Pro) leads on the differences that matter
The largest is rated ac power: 0.50 kW apart. 5 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 18 differencesHow alike are they
5
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
18 of 23 parameters
What actually differs
Parameter
SUN-10.5K-G
MOD 10KTL3-X2(Pro)
Difference
Rated AC power
10.50 kW
10.00 kW
0.50 kW apart
European efficiency
97.5 %
98.2 %
0.7 pp more efficient
Max DC voltage
550 V
1100 V
550 V apart
Max input current per tracker
25.0 A
20.0 A
5.0 A more headroom
Max efficiency
97.7 %
98.6 %
0.9 pp more efficient
Max AC power
11.60 kW
10.00 kW
1.60 kW apart
Max PV power
13.70 kW
15.00 kW
1.30 kW apart
DC/AC ratio
1.30
1.50
0.20 more oversizing headroom
Weight
15.7 kg
14.6 kg
1.1 kg lighter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
50.2 A
16.0 A
34.2 A apart
Start voltage
80 V
160 V
80 V earlier start
Max operating temperature
65 °C
60 °C
5 °C more heat tolerant
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
70-550 V
140-1000 V
70-550 V vs 140-1000 V
Strings per tracker
2
1
1 string apart
Dimensions
410x330x198 mm
387x425x178 mm
410x330x198 mm vs 387x425x178 mm
02
Full specification
Parameter
SUN-10.5K-G
MOD 10KTL3-X2(Pro)
Difference
AC output
Rated AC power
10.50 kW
10.00 kW
0.50 kW apart
Max AC power
11.60 kW
10.00 kW
1.60 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
50.2 A
16.0 A
34.2 A apart
PV input
Max PV power
13.70 kW
15.00 kW
1.30 kW apart
DC/AC ratio
1.30
1.50
+0.20 for MOD 10KTL3-X2(Pro)
Max DC voltage
550 V
1100 V
550 V apart
MPPT voltage range
70-550 V
140-1000 V
70-550 V vs 140-1000 V
Start voltage
80 V
160 V
-80 V for SUN-10.5K-G
MPP trackers
2
2
Same
Strings per tracker
2
1
1 string apart
Max input current per tracker
25.0 A
20.0 A
+5.0 A for SUN-10.5K-G
Efficiency
European efficiency
97.5 %
98.2 %
+0.7 pp for MOD 10KTL3-X2(Pro)
Max efficiency
97.7 %
98.6 %
+0.9 pp for MOD 10KTL3-X2(Pro)
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
15.7 kg
14.6 kg
-1.1 kg for MOD 10KTL3-X2(Pro)
Weight per kW
1.5 kg/kW
1.5 kg/kW
Same
Dimensions
410x330x198 mm
387x425x178 mm
410x330x198 mm vs 387x425x178 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
25 dB
-
Not published by Growatt
Max operating temperature
65 °C
60 °C
+5 °C for SUN-10.5K-G
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
Yes
Not published by Deye
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
-
8 yrs
Not published by Deye
03
Open all inverters
More useful comparisons
Same type, similar size
Sofar Solar
Deye SUN-10.5K-G vs SOFAR 10.5KTLM-G3
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Deye SUN-10.5K-G vs Growatt MOD 10KTL3-X
17 differences, the largest is rated ac power
Same type, similar size
Growatt
Deye SUN-10.5K-G vs Growatt MOD 11KTL3-X
18 differences, the largest is rated ac power
Same type, similar size
Sungrow
Growatt MOD 10KTL3-X2(Pro) vs Sungrow SG10KTL-M
8 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 10KTL3-X2(Pro) vs Sungrow SG10RT-20
9 differences, the largest is max input current per tracker
Same type, similar size
Sofar Solar
Growatt MOD 10KTL3-X2(Pro) vs SOFAR 11KTLX-G3
8 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.