Skip to main content
MOD 10KTL3-X2(Pro) vs SUN-10K-G03-LV 6 of 23 identical Swap Change inverters

Growatt MOD 10KTL3-X2(Pro) vs Deye SUN-10K-G03-LV

Growatt MOD 10KTL3-X2(Pro)
Growatt
MOD 10KTL3-X2(Pro)
10 kW 98.2 % euro Grid-tie
VS
Deye
SUN-10K-G03-LV
10 kW 97.8 % euro Grid-tie
The verdict

MOD 10KTL3-X2(Pro) leads on the differences that matter

The largest is max dc voltage: 300 V apart. 6 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
6 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 23 parameters
Parameter MOD 10KTL3-X2(Pro) SUN-10K-G03-LV Difference
Max DC voltage 1100 V 800 V 300 V apart
Max input current per tracker 20.0 A 25.0 A 5.0 A more headroom
European efficiency 98.2 % 97.8 % 0.4 pp more efficient
Max AC power 10.00 kW 11.00 kW 1.00 kW apart
Max PV power 15.00 kW 13.00 kW 2.00 kW apart
Weight 14.6 kg 28.0 kg 13.4 kg lighter
Weight per kW 1.5 kg/kW 2.8 kg/kW 1.3 kg/kW lighter
DC/AC ratio 1.50 1.30 0.20 more oversizing headroom
Nominal AC voltage 400 V 220 V 180 V apart
Max AC current 16.0 A 28.9 A 12.9 A apart
Start voltage 160 V 250 V 90 V earlier start
Max operating temperature 60 °C 65 °C 5 °C more heat tolerant
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 200-700 V 140-1000 V vs 200-700 V
Strings per tracker 1 2 1 string apart
Dimensions 387x425x178 mm 520x400x240 mm 387x425x178 mm vs 520x400x240 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MOD 10KTL3-X2(Pro) SUN-10K-G03-LV Difference
AC output
Rated AC power 10.00 kW 10.00 kW Same
Max AC power 10.00 kW 11.00 kW 1.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 220 V 180 V apart
Max AC current 16.0 A 28.9 A 12.9 A apart
PV input
Max PV power 15.00 kW 13.00 kW 2.00 kW apart
DC/AC ratio 1.50 1.30 +0.20 for MOD 10KTL3-X2(Pro)
Max DC voltage 1100 V 800 V 300 V apart
MPPT voltage range 140-1000 V 200-700 V 140-1000 V vs 200-700 V
Start voltage 160 V 250 V -90 V for MOD 10KTL3-X2(Pro)
MPP trackers 2 2 Same
Strings per tracker 1 2 1 string apart
Max input current per tracker 20.0 A 25.0 A +5.0 A for SUN-10K-G03-LV
Efficiency
European efficiency 98.2 % 97.8 % +0.4 pp for MOD 10KTL3-X2(Pro)
Max efficiency 98.6 % 98.6 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 14.6 kg 28.0 kg -13.4 kg for MOD 10KTL3-X2(Pro)
Weight per kW 1.5 kg/kW 2.8 kg/kW -1.3 kg/kW for MOD 10KTL3-X2(Pro)
Dimensions 387x425x178 mm 520x400x240 mm 387x425x178 mm vs 520x400x240 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural forced-air natural vs forced-air
Noise - 45 dB Not published by Growatt
Max operating temperature 60 °C 65 °C +5 °C for SUN-10K-G03-LV
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes - Not published by Deye
Integrated DC switch - Yes Not published by Growatt
Warranty
Warranty 8 yrs - Not published by Deye
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MOD 10KTL3-X2(Pro) vs Growatt MOD 10KTL3-X
5 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 10KTL3-X2(Pro) vs Sungrow SG10KTL-M
8 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 10KTL3-X2(Pro) vs Sungrow SG10RT-20
9 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.