Growatt MIN 4600TL-XH2 vs Huawei SUN2000-4.6KTL-L1
VS
The verdict
MIN 4600TL-XH2 leads on the differences that matter
The largest is max dc voltage: 50 V apart. 14 of 28 comparable parameters are identical, with 4 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
14
of 28 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 28 parameters
What actually differs
Parameter
MIN 4600TL-XH2
SUN2000-4.6KTL-L1
Difference
Max DC voltage
550 V
600 V
50 V apart
Max input current per tracker
16.0 A
12.5 A
3.5 A more headroom
Max AC power
4.60 kW
5.00 kW
0.40 kW apart
Max PV power
9.20 kW
6.90 kW
2.30 kW apart
DC/AC ratio
2.00
1.50
0.50 more oversizing headroom
European efficiency
97.5 %
97.7 %
0.2 pp more efficient
Weight
10.8 kg
12.0 kg
1.2 kg lighter
Start voltage
50 V
100 V
50 V earlier start
Max charge current
17 A
15 A
2 A faster charging
Ingress protection
IP66
IP65
IP66 vs IP65
Weight per kW
2.3 kg/kW
2.6 kg/kW
0.3 kg/kW lighter
MPPT voltage range
40-540 V
90-560 V
40-540 V vs 90-560 V
Battery voltage
360-550 V
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
360-550 V vs 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
Dimensions
350x375x160 mm
365x365x156 mm
350x375x160 mm vs 365x365x156 mm
02
Full specification
Parameter
MIN 4600TL-XH2
SUN2000-4.6KTL-L1
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
4.60 kW
5.00 kW
0.40 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
20.9 A
20.9 A
Same
PV input
Max PV power
9.20 kW
6.90 kW
2.30 kW apart
DC/AC ratio
2.00
1.50
+0.50 for MIN 4600TL-XH2
Max DC voltage
550 V
600 V
50 V apart
MPPT voltage range
40-540 V
90-560 V
40-540 V vs 90-560 V
Start voltage
50 V
100 V
-50 V for MIN 4600TL-XH2
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
16.0 A
12.5 A
+3.5 A for MIN 4600TL-XH2
Efficiency
European efficiency
97.5 %
97.7 %
+0.2 pp for SUN2000-4.6KTL-L1
Max efficiency
98.4 %
98.4 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
360-550 V
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
360-550 V vs 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
Max charge current
17 A
15 A
+2 A for MIN 4600TL-XH2
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
12.0 kg
-1.2 kg for MIN 4600TL-XH2
Weight per kW
2.3 kg/kW
2.6 kg/kW
-0.3 kg/kW for MIN 4600TL-XH2
Dimensions
350x375x160 mm
365x365x156 mm
350x375x160 mm vs 365x365x156 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Huawei
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Growatt MIN 4600TL-XH2 vs Huawei SUN2000L-4.6KTL
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MIN 4600TL-XH2 vs Growatt SPM 4600TL-HU
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MIN 4600TL-XH2 vs Growatt MIN 4600TL-XH
5 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Huawei SUN2000-4.6KTL-L1 vs Growatt MIN 4600TL-XA
7 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.