Growatt MIN 4600TL-X vs Ginlong Solis S6-GR1P4.6K-S
VS
The verdict
S6-GR1P4.6K-S leads on the differences that matter
The largest is max input current per tracker: 3.5 A more headroom. 9 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
9
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 22 parameters
What actually differs
Parameter
MIN 4600TL-X
S6-GR1P4.6K-S
Difference
Max input current per tracker
12.5 A
16.0 A
3.5 A more headroom
Max efficiency
98.4 %
97.7 %
0.7 pp more efficient
Max AC power
5.06 kW
4.60 kW
0.46 kW apart
Max PV power
6.44 kW
6.90 kW
0.46 kW apart
Weight
10.8 kg
9.0 kg
1.8 kg lighter
DC/AC ratio
1.40
1.50
0.10 more oversizing headroom
Start voltage
100 V
60 V
40 V earlier start
Weight per kW
2.3 kg/kW
2.0 kg/kW
0.4 kg/kW lighter
Ingress protection
IP65
IP66
IP65 vs IP66
Max AC current
22.0 A
20.9 A
1.1 A apart
Nominal AC voltage
220 V
230 V
10 V apart
MPPT voltage range
80-550 V
50-550 V
80-550 V vs 50-550 V
Dimensions
350x375x158 mm
371x330x161 mm
350x375x158 mm vs 371x330x161 mm
02
Full specification
Parameter
MIN 4600TL-X
S6-GR1P4.6K-S
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
5.06 kW
4.60 kW
0.46 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
220 V
230 V
10 V apart
Max AC current
22.0 A
20.9 A
1.1 A apart
PV input
Max PV power
6.44 kW
6.90 kW
0.46 kW apart
DC/AC ratio
1.40
1.50
+0.10 for S6-GR1P4.6K-S
Max DC voltage
550 V
550 V
Same
MPPT voltage range
80-550 V
50-550 V
80-550 V vs 50-550 V
Start voltage
100 V
60 V
-40 V for S6-GR1P4.6K-S
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
12.5 A
16.0 A
+3.5 A for S6-GR1P4.6K-S
Efficiency
European efficiency
97.1 %
97.1 %
Same
Max efficiency
98.4 %
97.7 %
+0.7 pp for MIN 4600TL-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
9.0 kg
-1.8 kg for S6-GR1P4.6K-S
Weight per kW
2.3 kg/kW
2.0 kg/kW
-0.4 kg/kW for S6-GR1P4.6K-S
Dimensions
350x375x158 mm
371x330x161 mm
350x375x158 mm vs 371x330x161 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
-
20 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Ginlong Solis
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 4600TL-X vs Growatt MIN 4600TL-X2 (Pro)
10 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MIN 4600TL-X vs GoodWe GW4600-SS
13 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Growatt MIN 4600TL-X vs Fronius Primo 5.0-1 AUS
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.