Growatt MIN 4600TL-X vs Fronius Primo 5.0-1 AUS
VS

Fronius International
Fronius Primo 5.0-1 AUS
4.6 kW
97.1 % euro
Grid-tie
The verdict
15 differences, and they point both ways
The largest is max dc voltage: 450 V apart. 8 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
8
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 23 parameters
What actually differs
Parameter
MIN 4600TL-X
Fronius Primo 5.0-1 AUS
Difference
Max DC voltage
550 V
1000 V
450 V apart
Max input current per tracker
12.5 A
18.0 A
5.5 A more headroom
Max PV power
6.44 kW
7.50 kW
1.06 kW apart
DC/AC ratio
1.40
1.63
0.23 more oversizing headroom
Weight
10.8 kg
21.5 kg
10.7 kg lighter
Weight per kW
2.3 kg/kW
4.7 kg/kW
2.3 kg/kW lighter
Max efficiency
98.4 %
98.1 %
0.3 pp more efficient
Max operating temperature
60 °C
55 °C
5 °C more heat tolerant
Max AC power
5.06 kW
5.00 kW
0.06 kW apart
Nominal AC voltage
220 V
230 V
10 V apart
MPPT voltage range
80-550 V
80-800 V
80-550 V vs 80-800 V
Start voltage
100 V
80 V
20 V earlier start
Strings per tracker
1
2
1 string apart
Dimensions
350x375x158 mm
645x431x204 mm
350x375x158 mm vs 645x431x204 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MIN 4600TL-X
Fronius Primo 5.0-1 AUS
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
5.06 kW
5.00 kW
0.06 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
220 V
230 V
10 V apart
Max AC current
22.0 A
21.7 A
Effectively the same
PV input
Max PV power
6.44 kW
7.50 kW
1.06 kW apart
DC/AC ratio
1.40
1.63
+0.23 for Fronius Primo 5.0-1 AUS
Max DC voltage
550 V
1000 V
450 V apart
MPPT voltage range
80-550 V
80-800 V
80-550 V vs 80-800 V
Start voltage
100 V
80 V
-20 V for Fronius Primo 5.0-1 AUS
MPP trackers
2
2
Same
Strings per tracker
1
2
1 string apart
Max input current per tracker
12.5 A
18.0 A
+5.5 A for Fronius Primo 5.0-1 AUS
Efficiency
European efficiency
97.1 %
97.1 %
Same
Max efficiency
98.4 %
98.1 %
+0.3 pp for MIN 4600TL-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
21.5 kg
-10.7 kg for MIN 4600TL-X
Weight per kW
2.3 kg/kW
4.7 kg/kW
-2.3 kg/kW for MIN 4600TL-X
Dimensions
350x375x158 mm
645x431x204 mm
350x375x158 mm vs 645x431x204 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
forced-air
natural vs forced-air
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
55 °C
+5 °C for MIN 4600TL-X
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Fronius International
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 4600TL-X vs Growatt MIN 4600TL-X2 (Pro)
10 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MIN 4600TL-X vs GoodWe GW4600-SS
13 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt MIN 4600TL-X vs Ginlong Solis S6-GR1P4.6K
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.