Growatt MIN 4600TL-X vs Ginlong Solis S6-GR1P4.6K
VS
The verdict
14 differences, and they point both ways
The largest is max dc voltage: 50 V apart. 9 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
9
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 23 parameters
What actually differs
Parameter
MIN 4600TL-X
S6-GR1P4.6K
Difference
Max DC voltage
550 V
600 V
50 V apart
Max efficiency
98.4 %
97.7 %
0.7 pp more efficient
Max input current per tracker
12.5 A
14.0 A
1.5 A more headroom
Max PV power
6.44 kW
6.90 kW
0.46 kW apart
Weight
10.8 kg
12.0 kg
1.2 kg lighter
DC/AC ratio
1.40
1.50
0.10 more oversizing headroom
Start voltage
100 V
60 V
40 V earlier start
Max AC current
22.0 A
23.8 A
1.8 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
Weight per kW
2.3 kg/kW
2.6 kg/kW
0.3 kg/kW lighter
Max AC power
5.06 kW
5.00 kW
0.06 kW apart
Nominal AC voltage
220 V
230 V
10 V apart
MPPT voltage range
80-550 V
50-520 V
80-550 V vs 50-520 V
Dimensions
350x375x158 mm
543x310x160 mm
350x375x158 mm vs 543x310x160 mm
02
Full specification
Parameter
MIN 4600TL-X
S6-GR1P4.6K
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
5.06 kW
5.00 kW
0.06 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
220 V
230 V
10 V apart
Max AC current
22.0 A
23.8 A
1.8 A apart
PV input
Max PV power
6.44 kW
6.90 kW
0.46 kW apart
DC/AC ratio
1.40
1.50
+0.10 for S6-GR1P4.6K
Max DC voltage
550 V
600 V
50 V apart
MPPT voltage range
80-550 V
50-520 V
80-550 V vs 50-520 V
Start voltage
100 V
60 V
-40 V for S6-GR1P4.6K
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
12.5 A
14.0 A
+1.5 A for S6-GR1P4.6K
Efficiency
European efficiency
97.1 %
97.1 %
Same
Max efficiency
98.4 %
97.7 %
+0.7 pp for MIN 4600TL-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
12.0 kg
-1.2 kg for MIN 4600TL-X
Weight per kW
2.3 kg/kW
2.6 kg/kW
-0.3 kg/kW for MIN 4600TL-X
Dimensions
350x375x158 mm
543x310x160 mm
350x375x158 mm vs 543x310x160 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
-
20 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 4600TL-X vs Growatt MIN 4600TL-X2 (Pro)
10 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MIN 4600TL-X vs GoodWe GW4600-SS
13 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Growatt MIN 4600TL-X vs Fronius Primo 5.0-1 AUS
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.