Growatt MIN 4600TL-X vs Fronius Primo 4.6-1
VS

Fronius International
Fronius Primo 4.6-1
4.6 kW
97.0 % euro
Grid-tie
The verdict
16 differences, and they point both ways
The largest is max dc voltage: 450 V apart. 7 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
7
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 23 parameters
What actually differs
Parameter
MIN 4600TL-X
Fronius Primo 4.6-1
Difference
Max DC voltage
550 V
1000 V
450 V apart
Max input current per tracker
12.5 A
18.0 A
5.5 A more headroom
Max AC power
5.06 kW
4.60 kW
0.46 kW apart
Max PV power
6.44 kW
6.90 kW
0.46 kW apart
Weight
10.8 kg
21.5 kg
10.7 kg lighter
Weight per kW
2.3 kg/kW
4.7 kg/kW
2.3 kg/kW lighter
Max efficiency
98.4 %
98.1 %
0.3 pp more efficient
DC/AC ratio
1.40
1.50
0.10 more oversizing headroom
Max AC current
22.0 A
20.0 A
2.0 A apart
Max operating temperature
60 °C
55 °C
5 °C more heat tolerant
Nominal AC voltage
220 V
230 V
10 V apart
MPPT voltage range
80-550 V
80-800 V
80-550 V vs 80-800 V
Start voltage
100 V
80 V
20 V earlier start
Strings per tracker
1
2
1 string apart
Dimensions
350x375x158 mm
645x431x204 mm
350x375x158 mm vs 645x431x204 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MIN 4600TL-X
Fronius Primo 4.6-1
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
5.06 kW
4.60 kW
0.46 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
220 V
230 V
10 V apart
Max AC current
22.0 A
20.0 A
2.0 A apart
PV input
Max PV power
6.44 kW
6.90 kW
0.46 kW apart
DC/AC ratio
1.40
1.50
+0.10 for Fronius Primo 4.6-1
Max DC voltage
550 V
1000 V
450 V apart
MPPT voltage range
80-550 V
80-800 V
80-550 V vs 80-800 V
Start voltage
100 V
80 V
-20 V for Fronius Primo 4.6-1
MPP trackers
2
2
Same
Strings per tracker
1
2
1 string apart
Max input current per tracker
12.5 A
18.0 A
+5.5 A for Fronius Primo 4.6-1
Efficiency
European efficiency
97.1 %
97.0 %
Effectively the same
Max efficiency
98.4 %
98.1 %
+0.3 pp for MIN 4600TL-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
21.5 kg
-10.7 kg for MIN 4600TL-X
Weight per kW
2.3 kg/kW
4.7 kg/kW
-2.3 kg/kW for MIN 4600TL-X
Dimensions
350x375x158 mm
645x431x204 mm
350x375x158 mm vs 645x431x204 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
forced-air
natural vs forced-air
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
55 °C
+5 °C for MIN 4600TL-X
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Fronius International
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 4600TL-X vs Growatt MIN 4600TL-X2 (Pro)
10 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MIN 4600TL-X vs GoodWe GW4600-SS
13 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Growatt MIN 4600TL-X vs Fronius Primo 5.0-1 AUS
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.