MIN 3600TL-XA leads on the differences that matter
The largest is max efficiency: 0.6 pp more efficient. 7 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
7
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 16 parameters
What actually differs
Parameter
MIN 3600TL-XA
GW3600-ES-C10
Difference
Max efficiency
98.2 %
97.6 %
0.6 pp more efficient
Max AC power
3.60 kW
3.96 kW
0.36 kW apart
Weight
10.8 kg
15.5 kg
4.7 kg lighter
Weight per kW
3.0 kg/kW
4.3 kg/kW
1.3 kg/kW lighter
Max AC current
16.0 A
18.0 A
2.0 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
Battery voltage
360-550 V
40~60 V
360-550 V vs 40~60 V
Dimensions
350x375x160 mm
415x560x204 mm
350x375x160 mm vs 415x560x204 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MIN 3600TL-XA
GW3600-ES-C10
Difference
AC output
Rated AC power
3.60 kW
3.60 kW
Same
Max AC power
3.60 kW
3.96 kW
0.36 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
16.0 A
18.0 A
2.0 A apart
PV input
Max PV power
-
7.20 kW
Not published by Growatt
DC/AC ratio
-
2.00
Not published by Growatt
Max DC voltage
-
600 V
Not published by Growatt
MPPT voltage range
-
60-550 V
Not published by Growatt
Start voltage
-
58 V
Not published by Growatt
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
32.0 A
Not published by Growatt
Efficiency
European efficiency
97.2 %
-
Not published by GoodWe
Max efficiency
98.2 %
97.6 %
+0.6 pp for MIN 3600TL-XA
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
360-550 V
40~60 V
360-550 V vs 40~60 V
Max charge current
17 A
-
Not published by GoodWe
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
15.5 kg
-4.7 kg for MIN 3600TL-XA
Weight per kW
3.0 kg/kW
4.3 kg/kW
-1.3 kg/kW for MIN 3600TL-XA
Dimensions
350x375x160 mm
415x560x204 mm
350x375x160 mm vs 415x560x204 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
forced-air
natural vs forced-air
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
10 yrs
-
Not published by GoodWe
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 3600TL-XA vs Growatt SPM 3600TL-HU
7 differences, the largest is warranty
Same type, similar size
Growatt
Growatt MIN 3600TL-XA vs Growatt MIN 3600TL-XH
2 differences, the largest is warranty
Same type, similar size
Growatt
Growatt MIN 3600TL-XA vs Growatt MIN 3600TL-XH2
2 differences, the largest is warranty
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.