Growatt MIN 3600TL-XA vs Growatt SPM 3600TL-HU
VS
The verdict
MIN 3600TL-XA leads on the differences that matter
The largest is warranty: 5 yrs longer. 12 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
12
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 19 parameters
What actually differs
Parameter
MIN 3600TL-XA
SPM 3600TL-HU
Difference
Warranty
10 yrs
5 yrs
5 yrs longer
European efficiency
97.2 %
97.6 %
0.4 pp more efficient
Max charge current
17 A
140 A
123 A faster charging
Weight
10.8 kg
26.0 kg
15.2 kg lighter
Weight per kW
3.0 kg/kW
7.2 kg/kW
4.2 kg/kW lighter
Battery voltage
360-550 V
40-60V
360-550 V vs 40-60V
Dimensions
350x375x160 mm
330x580x230 mm
350x375x160 mm vs 330x580x230 mm
02
Full specification
Parameter
MIN 3600TL-XA
SPM 3600TL-HU
Difference
AC output
Rated AC power
3.60 kW
3.60 kW
Same
Max AC power
3.60 kW
3.60 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
16.0 A
15.7 A
Effectively the same
PV input
Max PV power
-
5.40 kW
Not published by Growatt
DC/AC ratio
-
1.50
Not published by Growatt
Max DC voltage
-
600 V
Not published by Growatt
MPPT voltage range
-
150-550 V
Not published by Growatt
Start voltage
-
130 V
Not published by Growatt
MPP trackers
-
2
Not published by Growatt
Strings per tracker
-
1
Not published by Growatt
Max input current per tracker
-
22.0 A
Not published by Growatt
Efficiency
European efficiency
97.2 %
97.6 %
+0.4 pp for SPM 3600TL-HU
Max efficiency
98.2 %
98.1 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
360-550 V
40-60V
360-550 V vs 40-60V
Max charge current
17 A
140 A
+123 A for SPM 3600TL-HU
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
26.0 kg
-15.2 kg for MIN 3600TL-XA
Weight per kW
3.0 kg/kW
7.2 kg/kW
-4.2 kg/kW for MIN 3600TL-XA
Dimensions
350x375x160 mm
330x580x230 mm
350x375x160 mm vs 330x580x230 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
-
30 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
10 yrs
5 yrs
+5 yrs for MIN 3600TL-XA
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 3600TL-XA vs Growatt MIN 3600TL-XH
2 differences, the largest is warranty
Same type, similar size
Growatt
Growatt MIN 3600TL-XA vs Growatt MIN 3600TL-XH2
2 differences, the largest is warranty
Same type, similar size
GoodWe
Growatt MIN 3600TL-XA vs GoodWe GW3600N-EH
7 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.