Growatt MIN 3000TL-XH2 vs Growatt SPM 3000TL-HU
VS
The verdict
14 differences, and they point both ways
The largest is european efficiency: 0.5 pp more efficient. 13 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
13
of 27 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 27 parameters
What actually differs
Parameter
MIN 3000TL-XH2
SPM 3000TL-HU
Difference
European efficiency
97.1 %
97.6 %
0.5 pp more efficient
Max DC voltage
550 V
600 V
50 V apart
Max input current per tracker
16.0 A
22.0 A
6.0 A more headroom
Max PV power
6.00 kW
4.50 kW
1.50 kW apart
DC/AC ratio
2.00
1.50
0.50 more oversizing headroom
Max charge current
17 A
140 A
123 A faster charging
Weight
10.8 kg
26.0 kg
15.2 kg lighter
Weight per kW
3.6 kg/kW
8.7 kg/kW
5.1 kg/kW lighter
Start voltage
50 V
130 V
80 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
40-540 V
150-550 V
40-540 V vs 150-550 V
Battery voltage
360-550 V
40-60V
360-550 V vs 40-60V
Max AC current
13.6 A
13.1 A
0.5 A apart
Dimensions
350x375x160 mm
330x580x230 mm
350x375x160 mm vs 330x580x230 mm
02
Full specification
Parameter
MIN 3000TL-XH2
SPM 3000TL-HU
Difference
AC output
Rated AC power
3.00 kW
3.00 kW
Same
Max AC power
3.00 kW
3.00 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
13.6 A
13.1 A
0.5 A apart
PV input
Max PV power
6.00 kW
4.50 kW
1.50 kW apart
DC/AC ratio
2.00
1.50
+0.50 for MIN 3000TL-XH2
Max DC voltage
550 V
600 V
50 V apart
MPPT voltage range
40-540 V
150-550 V
40-540 V vs 150-550 V
Start voltage
50 V
130 V
-80 V for MIN 3000TL-XH2
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
16.0 A
22.0 A
+6.0 A for SPM 3000TL-HU
Efficiency
European efficiency
97.1 %
97.6 %
+0.5 pp for SPM 3000TL-HU
Max efficiency
98.2 %
98.1 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
360-550 V
40-60V
360-550 V vs 40-60V
Max charge current
17 A
140 A
+123 A for SPM 3000TL-HU
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
26.0 kg
-15.2 kg for MIN 3000TL-XH2
Weight per kW
3.6 kg/kW
8.7 kg/kW
-5.1 kg/kW for MIN 3000TL-XH2
Dimensions
350x375x160 mm
330x580x230 mm
350x375x160 mm vs 330x580x230 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
-
30 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MIN 3000TL-XH2 vs SolarEdge SE3000H
7 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MIN 3000TL-XH2 vs Growatt MOD 3000TL3-HU
15 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MIN 3000TL-XH2 vs Huawei SUN2000L-3KTL
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPM 3000TL-HU vs Growatt MOD 3000TL3-XH
16 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.