Growatt MIN 3000TL-XH2 vs Growatt MOD 3000TL3-HU
VS
The verdict
MOD 3000TL3-HU leads on the differences that matter
The largest is european efficiency: 0.7 pp more efficient. 13 of 28 comparable parameters are identical, with 4 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
13
of 28 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 28 parameters
What actually differs
Parameter
MIN 3000TL-XH2
MOD 3000TL3-HU
Difference
European efficiency
97.1 %
97.8 %
0.7 pp more efficient
Warranty
5 yrs
10 yrs
5 yrs longer
Max DC voltage
550 V
1000 V
450 V apart
Max input current per tracker
16.0 A
20.0 A
4.0 A more headroom
Max AC power
3.00 kW
3.30 kW
0.30 kW apart
Max charge current
17 A
25 A
8 A faster charging
Weight
10.8 kg
19.0 kg
8.2 kg lighter
Weight per kW
3.6 kg/kW
6.3 kg/kW
2.7 kg/kW lighter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
13.6 A
5.0 A
8.6 A apart
Start voltage
50 V
180 V
130 V earlier start
MPPT voltage range
40-540 V
140-1000 V
40-540 V vs 140-1000 V
Battery voltage
360-550 V
600-980 V
360-550 V vs 600-980 V
Dimensions
350x375x160 mm
468x408x202 mm
350x375x160 mm vs 468x408x202 mm
02
Full specification
Parameter
MIN 3000TL-XH2
MOD 3000TL3-HU
Difference
AC output
Rated AC power
3.00 kW
3.00 kW
Same
Max AC power
3.00 kW
3.30 kW
0.30 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
13.6 A
5.0 A
8.6 A apart
PV input
Max PV power
6.00 kW
6.00 kW
Same
DC/AC ratio
2.00
2.00
Same
Max DC voltage
550 V
1000 V
450 V apart
MPPT voltage range
40-540 V
140-1000 V
40-540 V vs 140-1000 V
Start voltage
50 V
180 V
-130 V for MIN 3000TL-XH2
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
16.0 A
20.0 A
+4.0 A for MOD 3000TL3-HU
Efficiency
European efficiency
97.1 %
97.8 %
+0.7 pp for MOD 3000TL3-HU
Max efficiency
98.2 %
98.3 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
360-550 V
600-980 V
360-550 V vs 600-980 V
Max charge current
17 A
25 A
+8 A for MOD 3000TL3-HU
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
19.0 kg
-8.2 kg for MIN 3000TL-XH2
Weight per kW
3.6 kg/kW
6.3 kg/kW
-2.7 kg/kW for MIN 3000TL-XH2
Dimensions
350x375x160 mm
468x408x202 mm
350x375x160 mm vs 468x408x202 mm
Ingress protection
IP66
IP66
Same
Cooling
natural
natural
Same
Noise
-
29 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
10 yrs
+5 yrs for MOD 3000TL3-HU
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MIN 3000TL-XH2 vs SolarEdge SE3000H
7 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MIN 3000TL-XH2 vs Growatt SPM 3000TL-HU
14 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MIN 3000TL-XH2 vs Huawei SUN2000L-3KTL
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 3000TL3-HU vs Growatt MOD 3000TL3-XH
9 differences, the largest is warranty
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.