Growatt MID 50K-HU vs Growatt WIT 50K-XHU
VS
The verdict
MID 50K-HU leads on the differences that matter
The largest is max dc voltage: 100 V apart. 15 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
15
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 25 parameters
What actually differs
Parameter
MID 50K-HU
WIT 50K-XHU
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max charge current
42 A
165 A
123 A faster charging
Weight
50.0 kg
90.0 kg
40.0 kg lighter
Weight per kW
1.0 kg/kW
1.8 kg/kW
0.8 kg/kW lighter
Max efficiency
98.6 %
98.1 %
0.5 pp more efficient
Max AC current
75.8 A
83.3 A
7.5 A apart
Start voltage
160 V
195 V
35 V earlier start
MPPT voltage range
200-1000 V
180-1000 V
200-1000 V vs 180-1000 V
Battery voltage
600-980 V
200-900V
600-980 V vs 200-900V
Dimensions
570x680x256 mm
585x920x320 mm
570x680x256 mm vs 585x920x320 mm
02
Full specification
Parameter
MID 50K-HU
WIT 50K-XHU
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
50.00 kW
50.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
75.8 A
83.3 A
7.5 A apart
PV input
Max PV power
100.00 kW
100.00 kW
Same
DC/AC ratio
2.00
2.00
Same
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
200-1000 V
180-1000 V
200-1000 V vs 180-1000 V
Start voltage
160 V
195 V
-35 V for MID 50K-HU
MPP trackers
-
4
Not published by Growatt
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
40.0 A
Same
Efficiency
European efficiency
97.2 %
-
Not published by Growatt
Max efficiency
98.6 %
98.1 %
+0.5 pp for MID 50K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
200-900V
600-980 V vs 200-900V
Max charge current
42 A
165 A
+123 A for WIT 50K-XHU
Backup power
30.0 kW
-
Not published by Growatt
Physical
Weight
50.0 kg
90.0 kg
-40.0 kg for MID 50K-HU
Weight per kW
1.0 kg/kW
1.8 kg/kW
-0.8 kg/kW for MID 50K-HU
Dimensions
570x680x256 mm
585x920x320 mm
570x680x256 mm vs 585x920x320 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
55 dB
55 dB
Same
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Growatt MID 50K-HU vs GoodWe GW50K-ET-10
14 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MID 50K-HU vs Ginlong Solis S6-EH3P50K-H
11 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt MID 50K-HU vs Deye SUN-50K-SG01HP3-EU-BM4
16 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.