Growatt MID 50K-HU vs Growatt WIT 50K-H-US / WIT 50K-HU-US
VS
The verdict
17 differences, and they point both ways
The largest is warranty: 5 yrs longer. 9 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.
See all 17 differencesHow alike are they
9
of 26 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
17 of 26 parameters
What actually differs
Parameter
MID 50K-HU
WIT 50K-H-US / WIT 50K-HU-US
Difference
Warranty
5 yrs
10 yrs
5 yrs longer
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
40.0 A
32.0 A
8.0 A more headroom
Max efficiency
98.6 %
98.0 %
0.6 pp more efficient
Max PV power
100.00 kW
109.20 kW
9.20 kW apart
Max charge current
42 A
151 A
109 A faster charging
Backup power
30.0 kW
100.0 kW
70.0 kW more backup
Weight
50.0 kg
60.0 kg
10.0 kg lighter
DC/AC ratio
2.00
2.18
0.18 more oversizing headroom
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
75.8 A
66.2 A
9.6 A apart
Start voltage
160 V
195 V
35 V earlier start
Ingress protection
IP66
NEMA 4X (IP66)
IP66 vs NEMA 4X (IP66)
MPPT voltage range
200-1000 V
180-800 V
200-1000 V vs 180-800 V
Battery voltage
600-980 V
750-1000V
600-980 V vs 750-1000V
Weight per kW
1.0 kg/kW
1.2 kg/kW
0.2 kg/kW lighter
Dimensions
570x680x256 mm
820x760x228 mm
570x680x256 mm vs 820x760x228 mm
02
Full specification
Parameter
MID 50K-HU
WIT 50K-H-US / WIT 50K-HU-US
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
50.00 kW
50.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
75.8 A
66.2 A
9.6 A apart
PV input
Max PV power
100.00 kW
109.20 kW
9.20 kW apart
DC/AC ratio
2.00
2.18
+0.18 for WIT 50K-H-US / WIT 50K-HU-US
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
200-1000 V
180-800 V
200-1000 V vs 180-800 V
Start voltage
160 V
195 V
-35 V for MID 50K-HU
MPP trackers
-
10
Not published by Growatt
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
32.0 A
+8.0 A for MID 50K-HU
Efficiency
European efficiency
97.2 %
-
Not published by Growatt
Max efficiency
98.6 %
98.0 %
+0.6 pp for MID 50K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
750-1000V
600-980 V vs 750-1000V
Max charge current
42 A
151 A
+109 A for WIT 50K-H-US / WIT 50K-HU-US
Backup power
30.0 kW
100.0 kW
+70.0 kW for WIT 50K-H-US / WIT 50K-HU-US
Physical
Weight
50.0 kg
60.0 kg
-10.0 kg for MID 50K-HU
Weight per kW
1.0 kg/kW
1.2 kg/kW
-0.2 kg/kW for MID 50K-HU
Dimensions
570x680x256 mm
820x760x228 mm
570x680x256 mm vs 820x760x228 mm
Ingress protection
IP66
NEMA 4X (IP66)
IP66 vs NEMA 4X (IP66)
Cooling
forced-air
forced-air
Same
Noise
55 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
5 yrs
10 yrs
+5 yrs for WIT 50K-H-US / WIT 50K-HU-US
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Growatt MID 50K-HU vs GoodWe GW50K-ET-10
14 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MID 50K-HU vs Ginlong Solis S6-EH3P50K-H
11 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt MID 50K-HU vs Deye SUN-50K-SG01HP3-EU-BM4
16 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.