MID 25KTL3-X2 (Pro.E)
vs
Sunny Tripower 25000TL-JP (STP 25000TL-JP-30)
7 of 21 identical
Swap
Change inverters
Growatt MID 25KTL3-X2 (Pro.E) vs SMA Solar Sunny Tripower 25000TL-JP (STP 25000TL-JP-30)
VS

SMA Solar
Sunny Tripower 25000TL-JP (STP 25000TL-JP-30)
25 kW
Grid-tie
The verdict
MID 25KTL3-X2 (Pro.E) leads on the differences that matter
The largest is max dc voltage: 100 V apart. 7 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
7
of 21 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 21 parameters
What actually differs
Parameter
MID 25KTL3-X2 (Pro.E)
Sunny Tripower 25000TL-JP (STP 25000TL-JP-30)
Difference
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
40.0 A
33.0 A
7.0 A more headroom
Max AC power
27.70 kW
25.00 kW
2.70 kW apart
Max PV power
37.50 kW
25.55 kW
11.95 kW apart
DC/AC ratio
1.50
1.02
0.48 more oversizing headroom
Weight
24.0 kg
61.0 kg
37.0 kg lighter
Weight per kW
1.0 kg/kW
2.4 kg/kW
1.5 kg/kW lighter
Nominal AC voltage
400 V
420 V
20 V apart
Max AC current
42.0 A
38.0 A
4.0 A apart
MPP trackers
3
2
1 tracker more
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
200-1000 V
390-800 V
200-1000 V vs 390-800 V
Start voltage
200 V
188 V
12 V earlier start
Dimensions
415x528x225 mm
682x661x264 mm
415x528x225 mm vs 682x661x264 mm
02
Full specification
Parameter
MID 25KTL3-X2 (Pro.E)
Sunny Tripower 25000TL-JP (STP 25000TL-JP-30)
Difference
AC output
Rated AC power
25.00 kW
25.00 kW
Same
Max AC power
27.70 kW
25.00 kW
2.70 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
420 V
20 V apart
Max AC current
42.0 A
38.0 A
4.0 A apart
PV input
Max PV power
37.50 kW
25.55 kW
11.95 kW apart
DC/AC ratio
1.50
1.02
+0.48 for MID 25KTL3-X2 (Pro.E)
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
200-1000 V
390-800 V
200-1000 V vs 390-800 V
Start voltage
200 V
188 V
-12 V for Sunny Tripower 25000TL-JP (STP 25000TL-JP-30)
MPP trackers
3
2
+1 trackers for MID 25KTL3-X2 (Pro.E)
Strings per tracker
-
3
Not published by Growatt
Max input current per tracker
40.0 A
33.0 A
+7.0 A for MID 25KTL3-X2 (Pro.E)
Efficiency
European efficiency
98.6 %
-
Not published by SMA Solar
Max efficiency
98.8 %
98.7 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
24.0 kg
61.0 kg
-37.0 kg for MID 25KTL3-X2 (Pro.E)
Weight per kW
1.0 kg/kW
2.4 kg/kW
-1.5 kg/kW for MID 25KTL3-X2 (Pro.E)
Dimensions
415x528x225 mm
682x661x264 mm
415x528x225 mm vs 682x661x264 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
forced-air
Same
Noise
-
51 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by SMA Solar
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MID 25KTL3-X2 (Pro.E) vs Growatt MID 25KTL3-X
6 differences, the largest is start voltage
Same type, similar size
Growatt
Growatt MID 25KTL3-X2 (Pro.E) vs Growatt MID 25KTL3-X1
5 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MID 25KTL3-X2 (Pro.E) vs GoodWe GW25K-MT
10 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.